Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The figure shows the Access Manager interface object settings panel.

 Image Modified

Departments tab

 Image Removed

Access levels tab

Image Removed

Time zones tab

Image Removed

Readers tab

Image Removed

Cameras tab

Image Removed

Others tab

Image Removed

Standard fields tab

Image Removed

Additional fields tab

Image Removed

The following table shows the elements in the Access Manager settings panel.

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

ID field

Automatically

Displays the identification number of the Access Manager interface object in the system

Whole nonnegative number

-

Depends on number of accessible Access Manager objects in the system

2

Name field

Setting the value in the field

Sets the number of the Access Manager object in the system

Latin, Cyrillic and special symbols

Access Manager

Case-insensitive character string (letters, digits, special symbols excepting > and <).

From 1 to 60 symbols

3

Disable checkbox

Settings checkbox

Sets the Access Manager object state in the system (enabled or disabled)

Boolean type

No

Yes – the Access Manager object is not used in the system.

No – the Access Manager object is used and active

4

Display drop-down list

Selecting the value in the list

Sets the Display parent object for the Access Manager object

Name of created Display objects

Parent Display name

Depends on the number of the Display objects

Position group

5

Fix position checkbox

Settings checkbox

Is used if it's required to specify coordinates of the Access Manager window and forbid its moving

Boolean type

No

Yes – position of the Access Manager window is fixed.

No – position of the Access Manager window can be changed.

6

Monitor drop-down list

Selecting the value in the list

Sets the number of monitor on which the Access Manager window will be displayed

List of accessible computer monitors

Monitor 1

Depends on the number of connected computer monitors

7




X:

Setting the value in the field

Sets X coordinate of the upper left corner of the Access Manager window

%  of screen width

0

From 0 to М*100, where М is a number of computer monitors

8

Y:

Setting the value in the field

Sets Y coordinate of the upper left corner of the Access Manager window

% of screen height

0

From 0 to М*100, where М is a number of computer monitors

9

W:

Setting the value in the field

Sets the Access Manager window width

%  of screen width

0

From 0 to М*100, where М is a number of computer monitors

10

H:

Setting the value in the field

Sets the Access Manager window height

% of screen height

0

From 0 to М*100, where М is a number of computer monitors

Access

level settings

levels, Users, Time zones, Departments groups

8

group11



Create checkbox

Settings checkbox

Checkbox

Sets possibility to create

access levels

the corresponding object in the Access Manager window

Boolean type

Yes

Yes

creating access levels

creating the corresponding object from the Access Manager window is allowed.

No

creating access levels

creating the corresponding object from the Access Manager window is forbidden.

12

Delete checkbox

Settings checkbox

Checkbox

Sets possibility to

delete access levels

delete the corresponding object in the Access Manager window

Boolean type

Yes

Yes

deleting access levels

deleting the corresponding object from the Access Manager window is allowed.

No

deleting access levels

deleting the corresponding object from the Access Manager window is forbidden.

13

Edit checkbox

Settings checkbox

Checkbox

Sets possibility to

edit access levels

edit the corresponding object in the Access Manager window

Boolean type

Yes

Yes

editing access levels

editing the corresponding object from the Access Manager window is allowed.

No

editing access levels

editing the corresponding object from the Access Manager window is forbidden.

User settings group

14
Out of groups
9Create users with APB checkbox
Settings checkbox
Checkbox

Sets

possibility to create users in the Access Manager window

the default setting for the user antipassback parameter 

Boolean type
Yes
No

Yes

– creating users from the Access Manager window is allowed.

No – creating users from the Access Manager window is forbidden.

15

Delete checkbox

Settings checkbox

- by default, the users are created with enabled antipassback

No - by default, the users are created with disabled antipassback

10

New departments are visible in root checkbox

Checkbox

Sets availability of new created departments in the Access Manager hierarchy root

Sets possibility to delete users in the Access Manager window

Boolean type

Yes

Yes

deleting users from

new departments are available in the Access Manager

window is allowed.

hierarchy root

No

deleting users from the Access Manager window is forbidden.

16

Edit checkbox

new departments are not available in the Access Manager hierarchy root

Departments tab

 Image Added

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Departments tree

Settings checkbox

Sets

possibility to edit users

available departments in the Access Manager window

Boolean type

Yes

Yes – editing users from

Set of boolean variables

Department will be available in the Access Manager window

is allowed.

No – editing users from the Access Manager window is forbidden.

17

Create users with APB checkbox

Settings checkbox

Sets default value for antipassback parameter

Boolean type

No

Yes – users are created with antipassback on default.

No – users are created without antipassback on default.

Departments settings group

18

Create checkbox

Settings checkbox

Sets possibility to create departments in the Access Manager window

Boolean type

Yes

Yes – creating departments from the Access Manager window is allowed.

No – creating departments from the Access Manager window is forbidden.

19

Delete checkbox

Settings checkbox

Sets possibility to delete departments in the Access Manager window

Boolean type

Yes

Yes – deleting departments from the Access Manager window is allowed.

No – deleting departments from the Access Manager window is forbidden.

20

Edit checkbox

Settings checkbox

Sets possibility to edit departments in the Access Manager window

Boolean type

Yes

Yes – editing departments from the Access Manager window is allowed.

No – editing departments from the Access Manager window is forbidden.

21

New departments are visible in root checkbox

Settings checkbox

Sets availability of new created departments in the Access Manager hierarchy root

Boolean type

Yes

Yes – new departments are available in the Access Manager hierarchy root

No – new departments are not available in the Access Manager hierarchy root

Departments tab

22

Departments tree

Settings checkbox

Sets available departments in the Access Manager window

Boolean type

Set of boolean variables

Department will be available in the Access Manager window if  checkbox is set close to it

Readers tab

if  checkbox is set close to it

Access levels tab

Image Added

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Mode drop-down listSelecting the value in the listSets the access restriction mode for access levels in the Access Manager interface object-Prohibition

Prohibition - restrict the access

Permission - allow the access

2Access levels treeCheckboxSpecifies the access levels, the access to which should be configuredBoolean typeA set of boolean variablesIf the checkbox is set for the access level, the selected access restriction mode will be applied to it in the Access Manager interface object
3Actions buttonSelecting the value in the listOpens a list of actions for managing the access levels tree--

Minimize - minimizes all access levels in the tree

Expand - expands all access levels in the tree

Select all - sets the checkboxes for all access levels

Remove all - removes checkboxes for all access levels

Search - opens the Access level or folder search window for access level or folder searching by the name or identifier

Time zones tab

Image Added

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Mode drop-down listSelecting the value in the listSets the access restriction mode for time zones in the Access Manager interface object-Prohibition

Prohibition - restrict the access

Permission - allow the access

2Time zones treeCheckboxSpecifies the time zones, the access to which should be configuredBoolean typeA set of boolean variablesIf the checkbox is set for thetime zone, the selected access restriction mode will be applied to it in the Access Manager interface object
3Actions buttonSelecting the value in the listOpens a list of actions for managing the time zones tree--

Minimize - minimizes all time zones in the tree

Expand - expands all time zones in the tree

Select all - sets the checkboxes for all time zones

Remove all - removes checkboxes for all time zones

Search - opens the Time zone or folder search window for time zone or folder searching by the name or identifier

Readers tab

Image Added

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

23

Confirm card entered by operator checkbox

Settings checkbox

Sets requirement  to confirm card code entering by operator

Boolean type

No

Yes – operator confirmation is required  to assign access card to user.

No –operator confirmation is not required to assign access card to user.

24

2

List of readers

Settings checkbox

Sets list of control readers used for entering user access cards

List of created reader objects in the system

Set of boolean variables

The reader will be available to enter user access card if checkbox is set close to it

Cameras tab

Image Added

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

25

Cameras column

Automatically

Displays list of Camera objects created on the Hardware tab of the System settings dialog window

List of created Camera objects in the system

Names of Camera objects

Depends on number of accessible Camera objects in the system

26

2

Use checkbox

Settings checkbox

Sets possibility to use camera for assigning photo to user in the Access Manager window

Boolean type

No

Yes – camera can be used for assigning photo.

No – camera can't be used for assigning photo

27

3Compression drop-down listSelecting the value in the listSets the compression level of the selected video stream-Do not compress

Do not compress - compression of the camera video stream is disabled

Level 1 - the lowest level of video stream compression

....

Level 5 - the highest level of video stream compression

4

Gateway drop-down list

Selecting the value in the list

Sets the Gateway object used for receiving video signal from camera

List of created Gateway objects in the system

Names of Gateway objects

Depends on number of accessible Gateway objects in the system

Others tab

Image Added

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

28

Full name drop-down list

Selecting the value in the list

Sets the way of defining of users record duplicates by name, surname, patronymic

List of available combinations

Not used

 Not used – adding users with the same full name is allowed.

Surname, name – adding users with the same name and surname and different patronymic is  forbidden.

Surname, name, patronymic – creating users with the same full name is forbidden.

29
2External ID checkboxSettings checkboxIndicates whether the users records should be checked for external ID duplicatesBoolean typeNo

Yescreating users with the same external ID is forbidden.

Nocreating users with the same external ID is allowed.

30
3Vehicle license plate checkboxSettings checkboxIndicates whether the users records should be checked for vehicle license plate number duplicatesBoolean typeNo

Yes – creating users with the same license plate number is forbidden.

No – creating users with the same license plate number is allowed.

31
4Non-empty departments checkboxSettings checkboxForbids to delete departments if there are users in themBoolean typeNo

Yes – non-empty departments cannot be deleted.

No – non-empty departments can be deleted.

32
5Assigned Access Levels checkboxSettings checkboxForbids to delete access levels if they are assigned to user(s)Boolean typeNo

Yes – assigned access levels cannot be deleted.

No – assigned access levels can be deleted.

33
6Assigned Time Zones checkboxSettings checkboxForbids to delete time zones if they are assigned to access levelsBoolean typeNo

Yes – assigned time zones cannot be deleted.

No – assigned time zones can be deleted.
34
7Recognition Server drop-down listSelecting the value in the listDisplays a list of Face Recognition Server objects created on the Hardware tab of the System Settings dialog boxList of Face Recognition Server objects created in the system-Depends on number of accessible Face Recognition Server objects in the system
8RestAPI port fieldSetting the value in the fieldSpecifies the communication port to connect to the Face Recognition Server through the REST API. By default, it is necessary to set the 10000 value.Number0-
9Module version fieldAutomaticallyDisplays the current version numberNumberCurrent version numberDepands on the current version of the module.

Standard fields tab

Image Added

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Name of field columnAutomaticDisplays a list of standard user fields-Names of standard user fields-
2Drop-down listSelecting the value in the listSpecifies the permissions to edit, specify, or hide the standard fields from the Access Manager interface object-Depends on the standard field

Edit - the field is displayed in the list of user parameters while viewing and editing and is available for editing

Hidden - the field is not displayed in the list of user parameters while viewing and editing

Read only - the field is displayed in the list of user parameters while viewing and editing but is not available for editing

Mandatory - this field is displayed and is required when creating a new user

3Category columnSetting the value in the fieldSpecifies the name of the category to which the standard field belongs-Depends on the standard fieldAny value

Additional fields tab

Image Added

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Name of field columnAutomaticDisplays a list of additional user fields-Names of additional user fields-
2Drop-down listSelecting the value in the listSpecifies the permissions to edit, specify, or hide the additional fields from the Access Manager interface object-Depends on the additional field

Edit - the field is displayed in the list of user parameters while viewing and editing and is available for editing

Hidden - the field is not displayed in the list of user parameters while viewing and editing

Read only - the field is displayed in the list of user parameters while viewing and editing but is not available for editing

Mandatory - this field is displayed and is required when creating a new user

3Category columnSetting the value in the fieldSpecifies the name of the category to which the additional field belongs-Depends on the additional fieldAny value