The Average queue length in time interval report provides the information on the average queue length. The

...

data can be presented in the form of a chart or a table.

Info
titleNote

The Average queue length in time interval report is related to the Queue Length Detector module (it is necessary to create the corresponding object in Intellect).


To create the Average queue length in time interval report, do the following:

  1. Select the Average queue length in time interval

...

  1.  report type (see Selecting a type of reports by Queue Length detectors). As a result the dialog box for specifying the report parameters will be displayed.
    Image Modified
  2. Set the following report parameters:
    Specify
    1. From the Period:

      From the

    period in the following way:
    1. Receiving data period drop-down list select the time period for which the report

      is

      should be created (1).

      If the User defined period
      Info
      titleNote

      If the Custom 2 time period is selected,

      enter the date of

      enter the start and end

      periods

      dates of the time period for which the report

      is

      should be created in

      the 

      the from

       and 

      and to

       fields

      fields using

      the 

      the Calendar

       tool

      tool. Click the Image Modified button near the corresponding field to use the Calendar tool.

      If the User defined 2 period is selected, additionally

      It is also necessary to enter the time of start and end periods

      for which the report is created

      using the Image Modified button.

      If another period type is selected, specifying the date of start and end periods is not needed.

    Enter a period of time (in minutes) between load values in the Step (min.) field (2). The average values of queue length for the specified interval are displayed in the report

    1. In the Data averaging interval (min.) field (2), enter the time period in minutes between the congestion values of the monitored area in the report. The report displays the average values of the queue length over a time equal to the calculation step.

      Info
      titleNote
    .
    1. If the average value is null for all such intervals

    in the specified
    1. over a given period,

    this
    1. that period will not be

    reflected
    1. displayed in the report.

    It
    1. In this case, it is recommended to change the calculation step

    in this case
    1. .


    2. In the Detectors field (3), set the checkboxes for
    the 
    1. those Queue Length Detector objects
    that will supply the information for
    1. which information should be displayed in the report
    (3)
    1. .
    If you want to view a report as a chart, set the corresponding
    1. Set the Chart checkbox (4), if it is necessary to display the report in the form of a chart.
    2. From the Time zone drop-down list (5), select time zone by which report is to be created

    (5)
    1. .

      Info
      titleNote.

      Time zones created in the Intellect software package which have only one time period and haven't got any inclusions are available to select. Selection of week days is not performed. Detailed information about creation and using of time zones is presented in the Creating and using time

    zones section
    1. schedules section.


    2. From the
    Orientation
    1. Layout drop-down list (6), select the orientation of the printed report page: Portrait, Landscape
    (6)
    1. .
  3. To create a report, click Execute (7). As a result, the report by the average queue length in time interval with specified parameters will be displayed.
    View of the report in the form of a table:
    Image Modified

...

  1. View of

...

  1. the report

...

  1. in the form of a chart. If more than one detector is used, the data from each detector will be displayed in its own color.
    Image Modified