- Any user can control a PTZ device when it is not controlled by another user with the interface of the same control priority.
- If a user who controls interface object with a higher priority delegates control to a user who controls interface object with a lower priority, then this procedure is delayed. The priority delay time is set with the help of the tweaki.exe utility (Intellect Axxon PSIM Advanced Setup).
To change the priority delay time using the tweaki.exe utility, do the following:
- Run the tweaki.exe utility in the Tools folder of the INTELLECT™ Axxon PSIM™ software installation directory.
- Select the PTZ section (1).

- Specify the value of PTZ control priority delay in the Delay by priority (ms) field (2).
The delay parameter is given in milliseconds. The default value is 30000. - Click the OK button to save the changes (3).
...