Go to documentation repository
...
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range | ||||
| 1 | Country drop-down list | Select value from the list | For AUTO-Uragan, VIT, RoadAR, LPR IntelliVision software modules | |||||||
| Selection of the country which numbers it is necessary to recognize | List of available national license plate templates | Depending on the recognition module | Depending on the number of available national license plate templates | |||||||
| Module drop-down list | Select value from the list | For CARMEN-Auto, ARH-Carriages, ARH-Containers software modules | ||||||||
| Selection of the license plate recognition SDK | List of license plate recognition SDK | Depending on the recognition module | Depending on the number of installed license plate recognition SDK | |||||||
2 | Select cameras group | |||||||||
License plates recognition drop-down list | Select value from the list | Main video camera for license plate recognition | List of available Camera objects | Camera 1 | Depending on the number of available Camera objects | |||||
Synchronous recording drop-down list | Select value from the list | Additional video camera operating together with the main camera | List of available Camera objects | None | Depending on the number of available Camera objects | |||||
Auto recording checkbox | Set the checkbox | Enabling the automatic recording on the LP number recognition | Boolean | No | Yes – automatic recording enabled, No – automatic recording disabled | |||||
Auto recording, s field | Enter the value in the text field | Setting the auto recording duration (in seconds) | Seconds | 10 | 0 - 1000 | |||||
| Enable on motion detection trigger checkbox | Set the checkbox | Starting auto recording on receiving an event from the motion detector | Boolean | No | For normal mode: Yes – if the camera is armed, the LPR channel scans all video images until the basic motion detection of the PSIM software is in the Alarm mode; If the camera is not armed, the LPR doesn't work, but manual start using scripts is available (see item 6 in the Scripts used in the Auto - PSIM software package section). Recognition will process frames until the stop command will be done. No – the LPR channel scans video images permanently. For Parking mode: Yes –if the camera is armed, the LPR channel scans all video images, until the plate will be recognized, after it recognition stops even if the Alarm mode is still in process and procedure repeats when the new trigger of alarm is activated; if the camera is not armed, the LPR doesn't work, but manual start using scripts is available (see item 6 in the Scripts used in the Auto - PSIM software package section). Recognition will process frames until the plate will be recognized and then will stop before new manual start. No – the LPR channel scans video images permanently | |||||
| Reduce large resolution checkbox | Set the checkbox | Frame handling setup | Boolean | Yes | Yes – the lesser frame is stretched, the bigger one is cut off No– the lesser frame is stretched, the bigger one is handled without changes | |||||
3 | Settings button Not available for:
| Click the button | Access to frame sign settings | - | - | - | ||||
| 4 | Entry checkbox | Set the checkbox | The vehicle's movement direction will be treated as Entry to the territory | Boolean | No | Yes - The LPR channel considers the vehicle's movement direction as Entry to the territory. No - The LPR channel does not consider the vehicle's movement direction as Entry to the territory. Note. This setting is taken into account in the PSIM Web Report System when working with Auto reports (see PSIM Web Report System. User Guide). | ||||
...
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
|---|---|---|---|---|---|---|
| 1 | Speed camera settings group | |||||
Speed camera settings drop-down list | Select the value from the list | Selecting the speed camera to work together with LPR channel | List of available Speed traps objects | Not specified | Depending on the number of available Speed traps objects | |
Synchronization time field | Enter the value in the text field | The time it takes the car to move from the point of speed detection by the Speed traps server module to the viewing zone of the camera | Milliseconds | Not specified | 0 - 20000 | |
Filter events from speed camera checkbox | Set the checkbox | Enables saving the first speed detected only | Boolean | No | Yes – only the first detected speed value is used, others are ignored until the delay expires or the number is recognized No – all speed values are used | |
| 2 | Get speed from video checkbox Available for:
| Set the checkbox | Enables estimation of speed by video via the Auto - PSIM algorithm | Boolean | No | Yes – vehicle speed is estimated by video, the results are displayed over video image as captions. No – vehicle speed is not estimated by video. |
| Configuration button | Click the button | Opens a dialog box to set a line segment | - | - | - | |
| Distance field | Enter the value in the text field | Sets length of the line segment in the Get speed from video dialog box, in centimeters | Number | - | >0 | |
| Permitted speed field | Enter the value in the text field | Sets permitted vehicle speed on the observed lane | Number | 60 | >0 | |
| Alarm on speed limit field | Enter the value in the text field | Sets maximum vehicle speed. If this speed is exceed, an alarm event is generated | Number | 80 | >0 | |
...