Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Open the Programming tab in the System settings dialog box (1).
  2. Create a Macro object under the Macros object in the Programming tab (2). Specify the object's ID and name.

    Info
    titleNote

    The Macro object is necessary to refer to Axxon PSIM™ core and to display the Operator query panel on the screen.


  3. Open the Hardware tab in the System settings dialog box (3).
  4. Create the Operator query panel object under the Computer object in the Hardware tab (4).
  5. Specify the file name (without extension) of the dialog box, used for PTZ device control, in the ID field (5). The file should be created with the ArpEdit utility and saved in the program folder of the Axxon PSIM™ installation directory (see Creating a dialog box form). You can also request dialog box file examples by contacting AxxonSoft technical support.Image Removed
  6. To activate the moving option for the Operator query panel object, set the Allow moving checkbox checked (6).
  7. Specify the X and Y coordinates of the Operator query panel position on the screen in the relevant fields. The X and Y settings correspond to the screen coordinates of the top left corner of the Operator query panel and are shown as percentage of the horizontal and vertical screen sizes correspondingly (7).
  8. Select the type of the Macro objects in the list of objects and events (8).
  9. Specify the ID of the Macro object, created to call up the Operator query panel (9).
  10. The name of selected Macro object is automatically displayed in the Name column (10).
  11. Select the Action executed item in the list of possible events (11).
  12. To save the changes, click the Apply button (12).