Go to documentation repository
...
Events registered by alarm objects with no type assigned and events escalated from a lower level are displayed in the Current events tab. The event control panel is at the top of the tab, and the information on events is at the bottom of the tab.
The details of event display:
...
...
...
...
| Info | ||
|---|---|---|
| ||
Temporary images (event screenshots) are stored in the C:\Users\<User name>\AppData\Local\Temp\OperatorProtocol folder. They are automatically deleted at normal Axxon PSIM shutdown or restart. |
On the right there is a checklist of actions that must should be performed during the event processing. This list is set up by the Administrator during the Operator Protocol configuration. After you perform the required action, set the checkbox next to it, and the information about the task completion will be added to the comment field along with the date and time indication.
...
The button names can be changed during the Operator Protocol configuration.
| Info | ||
|---|---|---|
| ||
When you select the event cell or line, the camera (linked to the corresponding object) activation event is generated. If the Active monitor is configured in the system (see Configuring the display mode for camera boxes), then video from the corresponding camera is displayed in it. If several cells are selected, then cameras are displayed one-by-one on the Active monitor. |
After the type is assigned to the event, it is removed from the Current events tab in the Operator protocol window. If the event (after being processes) is not removed from other Operator protocols when configuring the Operator protocol (see Setting the options for handling events in the Operator protocol), then the processed event is marked grey in other Operator protocol windows. But other operators can process this event once again.
| Info | ||
|---|---|---|
| ||
If all non-processed events are to be assigned with the type of the selected event, then set the Apply to all checkbox. |
In order to delay the event processing once for the time period specified when configuring the Operator protocol, click the Delay button. The event will not be removed from the Operator protocol windows and it will not be marked grey in in other Operator protocols.
| Info | ||
|---|---|---|
| ||
If the time of waiting for the response from the Operator (specified in the settings of the If the time of waiting the respond from operator (specified in the settings of the Operator protocol object) (see Administrator's Guide) is exceeded, then the event is escalated and if the chief interface is not assigned to the Operator protocol, then it is removed from the Current events tab and the Non-processed type is assigned. When Axxon PSIM is restarted, the non-processed events are saved. |
...
If the bookmark for the selected events is to be created in the archive, then set the Set the bookmark checkbox checked before processing the event. The comment will be used as the bookmark name. See List of bookmarks.
...