Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. In the Time schedule field (1), specify the time schedule of the script execution: Always, Never or one of the schedules created earlier (1, see Creating and configuring Time schedules). The default value is Never.

  2. In the Computers field (2), select the computers (kernels) where the script should run.

    Info
    titleNote

    By default, the script will run on all computers (kernels). The list displays only the computers registered in the Hardware tab of the System settings dialog window.


  3. Click the Apply button.

Creating and editing a script

To create a script in JScript in Axxon PSIM, do the following:

  1. Click the Editor-Debugger button (3) at the bottom of the Script system object panel to open the Editor-Debuggerutility.

    Info
    titleNote

    Use the Editor-Debugger utility to create, edit and save scripts in JScript. The settings panel of the Script system object displays the text of the saved script that can also be edited. 


  2. In the Editor-Debugger utility window, open the Debug-edit script list and select the Script object you want to edit (for example, the Script 1 object, as in the figure below).
  3. In the Script field, enter the text of the script in JScript programming language (see Examples of scripts in JScript language).

  4. Run the script using a test event. To create a test event, select Debug and edit → Edit test event.
    The Test message window will open containing the fields for setting the event parameters.

...

When working with script in the Editor-Debugger utility, you can undo the last action or return the last action. To undo the last action, press the Ctrl+Z key combination. To return the last action, press the Ctrl+Y key combination.

Info
titleNote

For your convenience, when editing the script, the cursor position is saved when saving the script or when switching between the scripts in the Editor-Debugger utility window during a session, i.e. until Axxon PSIM is restarted.

...