During installation you may have to reboot the system. After rebooting the installation will continue automatically. |
When Redist.exe process ends and not listed in Windows Task Manager, the installation is complete.
...
| Note | ||
|---|---|---|
| ||
Occasionally, when installing the Bosch VideoSDK driver, the CLI window opens. To continue with installation, close this window. |
/ADD and /REMOVE values:
x86 | x64 |
| Acrobat | Acrobat |
| BaseProduct | BaseProduct |
| IPDriverPack_x86 | IPDriverPack_x86 |
| Guardant_x86 | Guardant_amd64 |
| Postgres | Postgres |
| dotnetfx35_x86 | dotnetfx35_x86 |
| Redist2005_x86 | Redist2005_x86 |
| Redist2010_x86 | Redist2010_x86 |
| DetectorPack | DetectorPack |
Installation options:
Installation options | Description |
| QUICKLAUNCH_SHORTCUT='1' | Create shortcut: 1 − Yes (default) 0 − No |
| DESKTOP_SHORTCUT='1' | Copy shortcut to desktop: 1 − Yes (default) 0 − No |
| INSTALLDIR='[%ProgramFiles%\AxxonSoft\Axxon One]' | Axxon One installation folder |
| NGP_IFACE_WHITELIST="0.0.0.0/0" | Network interfaces. The default value is "0.0.0.0/0" (all available network interfaces). Format of network interfaces: "IP-address1 / number of unit bits in the mask, IP-address2 /number of unit bits in the mask" |
| NGP_ALT_ADDR="0.0.0.0" | Setting the outside local address for a Server behind the NAT). Format of network interfaces: "IP Address1 or DNS-name1, IP address2 or DNS Name2" |
| PORT_RANGE_START="20111" | The initial value of the port range for Server. 20111 − default |
| PORT_RANGE_COUNT="100" | Number of ports in use. The minimum number is 20. 100 − default |
Options for Server and Client installation | |
PATH_TO_DATA = 'X:\AxxonOneData', | Directory for storing the log database and metadata database. Default is X:\AxxonOneData. The PATH_TO_DATA parameter should be after the INSTALLDIR parameter |
| FBUSER_TYPE='DEFAULT' | User account for file explorer: DEFAULT − create a new account; the default name selected will be AxxonFileBrowser SYSTEM − select an account from the Local System SPECIFY − create a new account; choose the user name and password |
| FBUSER_NAME='[AxxonFileBrowser]' | Setting a user name and password for an account in file explorer. When you choose SPECIFY of the FBUSER_TYPE parameter |
| FBUSER_PSW='[Axxon2.0.0]' | |
| CONFIG_PATH='[CommonAppDataDirectory]' | Path to configurations files and folders |
| DOMAIN_NAME_TYPE = '[NewDomain]' | Select Axxon-domain: NewDomain − create new Axxon Domain (default) WithoutDomain − do NOT add Server to Axxon Domain TheSameDomain − use existing Axxon-domain |
| WHATDBUSE = '[EXIST]' | EXIST − use existing log DB (default) NEWDB − create new DB |
| WHATVMDADBUSE = '[EXIST]' | EXIST − use existing object tracking DB (default) NEWDB − create new DB |
The command for silent installation of Axxon One may look like:
setup.exe /quiet /norestart /debug /INSTALLTYPE="ServerClient" /REMOVE="Guardant_x86" /CMD="CREATE_QUICKLAUNCH_SHORTCUT=\"0\" PORT_RANGE_COUNT=\"50\" DOMAIN_NAME_TYPE=\"WithoutDomain\""
This will launch installation with the following options:
| Quiet mode |
...
| /quiet |
...
| No reboot |
...
| /norestart |
...
| Log installation to file |
...
| /debug |
...
Server and Client |
...
| /INSTALLTYPE="ServerClient" |
...
No Guardant drivers |
...
| /REMOVE="Guardant_x86" |
...
| And with the following properties |
...
| : | /CMD= |
...
|
...
| ="CREATE_QUICKLAUNCH_SHORTCUT=\"0\" |
...
|
...
| PORT_RANGE_COUNT="50" |
...
|
...