Go to documentation repository
Page History
...
| Note | ||
|---|---|---|
| ||
Occasionally, when installing the Bosch VideoSDK driver, the CLI window opens. To continue with installation, close this window. |
/ADD and /REMOVE values:
x86 | x64 | |
| Acrobat | Acrobat | BaseProduct |
| BaseProduct | ||
| IPDriverPack_x86 | IPDriverPack_x86 | |
| Guardant_x86Guardant_amd64 | ||
| Postgres | Postgres | dotnetfx35_x86 |
| dotnetfx35_x86Redist2005_x86 | ||
| Redist2005_x86 | ||
| Redist2010_x86 | Redist2010_x86 | |
| DetectorPack | DetectorPack |
Installation options:
Installation options | Description |
| QUICKLAUNCH_SHORTCUT='1' | Create shortcut:
|
| DESKTOP_SHORTCUT='1' | Copy shortcut to desktop:
|
| INSTALLDIR='[%ProgramFiles%\AxxonSoft\AxxonNext]' | Axxon Next installation folder |
| NGP_IFACE_WHITELIST="0.0.0.0/0" | Network interfaces The default value is "0.0.0.0/0" (all available network interfaces) Format of network interfaces: "IP-address1 / number of unit bits in the mask, IP-address2 /number of unit bits in the mask" |
| NGP_ALT_ADDR="0.0.0.0" | Setting the outside local address for a Server behind the NAT). Format of network interfaces: "IP Address1 or DNS-name1, IP address2 or DNS Name2" |
| PORT_RANGE_START="20111" | The initial value of the port range for Server. 20111 — default. |
| PORT_RANGE_COUNT="100" | Number of ports in use. The minimum number is 20. 100 — default. |
Options for Server and Client installation | |
| PATH_TO_DATA = 'X:\AxxonNextData', where X is the letter of the disk with the most free memory | Directory for storing the log database and metadata database. Default is X:\AxxonNextData. The PATH_TO_DATA parameter should be after the INSTALLDIR parameter. |
| FBUSER_TYPE='DEFAULT' | User account for file explorer:
|
| FBUSER_NAME='[AxxonFileBrowser]' | Setting a user name and password for an account in file explorer. When you choose SPECIFY of the FBUSER_TYPE parameter |
| FBUSER_PSW='[Axxon2.0.0]' | |
| CONFIG_PATH='[CommonAppDataDirectory]' | Path to configurations files and folders |
| DOMAIN_NAME_TYPE = '[NewDomain]' | Select Axxon-domain:
|
| WHATDBUSE = '[EXIST]' |
|
| WHATVMDADBUSE = '[EXIST]' |
|
The command for silent installation of Axxon Next may look like:
setup.exe /quiet /norestart norestart /debug debug /INSTALLTYPE="ServerClient" /REMOVE="Guardant_x86amd64" /CMD="CREATE_QUICKLAUNCH_SHORTCUT=\"0\" PORT_RANGE_COUNT=\"50\" DOMAIN_NAME_TYPE=\"WithoutDomain\""
...
- Quiet mode (/quiet);
- no reboot (/norestart);
- log installation to file (/ debug);
- Server and Client (/ INSTALLTYPE = "ServerClient");
- No Guardant drivers (/ REMOVE = "Guardant_x86amd64");
- And with the following properties (/ CMD =):
- no shortcut (="CREATE_QUICKLAUNCH_SHORTCUT=\"0\");
- 50 ports for Server (PORT_RANGE_COUNT="50");
- Server NOT added to Axxon-domain (DOMAIN_NAME_TYPE = '[WithoutDomain]').