The Event counter object is designed used to register and count events of a certain type, occurring at the pre-defined specified objects and registered by the Axxon PSIM™ systemPSIM.

The settings panel for the Event counter object is shown in the figure.

Table describes the setting parameters of the settings corresponding to the elements of the settings panel of the Event counter object.

 

Parameter

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Event counter object in the digital distributed video surveillance system .with the distributed architecture

Sequence of numbers

-

Depends on the number of the Event counter objects in the digital distributed video surveillance system .with the distributed architecture

2

Name*

Specify Enter the value in into the field

Sets the name of the Event counter object in the digital distributed video surveillance system .with the distributed architecture

Latin, Cyrillic and service characters

Event counter

A line containing a sequence of any symbols characters (letters, digits, service characters apart from except > and < symbolscharacters), not case-sensitiveinsensitive.

Number of symbols – charactersfrom 1 to 60.

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the Event counter object (enabled or disabled) in the digital distributed video surveillance system .with the distributed architecture

Boolean typeNo

Clear

Yes – the Set—the Event counter object is disabled.No

Clearthe Event counter object is enabled.

4

Computer

Select in the value from the list

Sets the Computer parent Computer object of the digital distributed video surveillance systemsystem with the distributed architecture, to which the given Event counter object refers.belongs

Name of the Computer objects registered in the system

Name of the Computer parent Computer object.

Depends on the number of the Computer objects in the digital distributed video surveillance system with the distributed architecture

The Start to count group

5

From the date of (activation)

Set the checkbox

Allows setting manually the start to count date and time manually.

 

 of the count start



Boolean type

Yes

Set

Set—the Yes – the Start to count date and time of the count start are set manually.

Clear—the No – The Start to count date and time of the count start are set at the date and time, when the Event counter object was last modified.

From the date of (date)

Specify Enter the value in into the field or select it in the dropdown list.the value from the drop-down list

Sets the Start to count date.date of the count start

DATE:MONTH:YEAR

Current system date

09.1752 – 12.9999

From the date of (time)

Specify Enter the value in into the field

Sets the Start to count time.time of the count start

HOURS:MINUTES:SECONDS

Current system time

00:00:0 -23:59:59

6

From the moment of counters counter settings changingare changed

Set the checkbox

Sets the Start to count date and time of the count start at the date and time, when the Event counter object was last modified.

Boolean type

No

Clear

Set—the Yes – the Start to count date and time of the count start are set at the date and time, when the Event counter object was last modified.No – the Start to count

Clear—the date and time of the count start are set manually.

7

One counter for all events

Set the checkbox

Sets the same counter for all events referred to presented in the Objects and events group of the given Event counter object.

Boolean type

YesSet

Yes – Only Set—only one counter will be used for counting all events specified in the Objects group.

No – the Clear—different events are counted by different counters (each event is counted by an individual a separate counter).

The Counter notification Signal group

8

On By time (activation)

Set the checkbox

Enables a regular notification in preset periods a set period of time.

 


Boolean type

Yes

Set

Set—the notification by time Yes – on time notification is enabled.

Clear—the notification by time No – on time notification is disabled (notification by quantity of events is enabled).

On By time (every)

Specify Enter the value in into the field

Sets a the notification period as a time periodinterval. Notification is performed irrespective regardless of on count start time at 00 minutes 00 seconds of every hour (or at 00 hours 00 minutes 00 seconds of every day , depending on the time unit settings)

Sequence of numbers

0

0 - 2147483648

On By time (time unit)

Select the value in from the list

Sets a time unit for the given notification.

Line

Hours

Hours

Days

By quantity of events (activation)

Set the checkbox

Enables a regular notification about events  starting starting from the preset set one.

Boolean type

NoClear

YesSet—the notification by quantity of events is enabled.

NoClear—the notification by quantity of events is disabled (on the notification by time notification is enabled).

By quantity of events (quantity of events)

Specify Enter the value in into the field

Sets a the number of event starting from which the notification will be performed.

Example: if the parameter has the value 5 value, then notification will be performed by every event starting from 5 (5, 6, 7, 8, etc.)

Sequence of numbers

0

0 - 2147483648

The Reset counters group

9

On time By (activation)

Set the checkbox

Enables a cyclic counter reset in a preset set time period.

 

 



Boolean type

YesSet

Yes – a Set—a cyclic reset in a preset set time period is enabled.

No – a Clear—a cyclic reset in a preset set time period is disabled (By quantity of events (a cyclic reset by quantity of events is enabled).

On time By (every)

Specify Enter the value in into the field

Sets a reset period as a time periodinterval.

Reset is performed irrespective regardless of on the time of the count start at 00 minutes 00 seconds of every hour (or at 00 hours 00 minutes 00 seconds of every day , depending on the time unit settings).

Sequence of numbers

0

0 - 2147483648

On time By (time unit)

Select in the value from the list

Sets a time unit for the given counters reset.

Line

Hours

Hours

Days

By quantity of events (activation)

Set the checkbox

Enables a counter reset performed upon occurrence of a preset number of events. when it reaches a specified number of event


Boolean type

No

Clear

Set—a  Yes – a cyclic reset upon occurrence of reaching a preset specified number of events is enabled.

No – a Clear—a cyclic reset upon occurrence of reaching a preset specified number of events is disabled (a cyclic reset on by time is enabled).

By quantity of events (quantity of events)

Specify Enter the value in into the field

Sets a reset period for counters as a number by quantity of events.

Sequence of numbers

0

0 - 2147483648

The Objects and events group

10

Object's type

Select in the value from the list

Sets the type of object for which the events are to be counted.

Types Names of the types of objects registered in the system.

Not set

Depends on the number types of object types objects registered in the digital distributed video surveillance system .with the distributed architecture

Identifier

Select in the value from the list

Sets  Sets the identification number of an object of the preset selected type for which the events are to be counted.

Sequence of numbers

Not set

Depends on the number of objects of the given type in the digital distributed video surveillance system .with the distributed architecture

Object Object’s name

Automatically

Displays the identification number of the selected object.

Latin, Cyrillic and service characters

Not set

Object name aith with the preset specified identifier.

11

Event

Select in the value from the list

Sets an event that is to should be counted.

Latin, Cyrillic and service characters

Not set

Depends on the number of types of objects registered in the digital distributed video surveillance system .with the distributed architecture

*The name Name of the element is not isn't displayed in the settings panel of the given object.