Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The Security zone object is used for the general configuration of Axxon PSIM.

panel is designed to define the common settings of the Axxon PSIM system. The settings panel of the Security zone object is shown in the figurefigures.

...

The Basic settings tab.

Image Removed Image Added

The RabbitMQ tab.

Image Added

The table Table describes the setting parameters of the settings corresponding to the elements of the settings panel of the Security zone object.

Parameter

Method for

entering

setting the parameter value

Parameter description

Symbols used

Representation

Default value

Value range

The Settings group

1
Event viewer clearing
Protocol clear timeEnter
a
the value
in
into the field using the up and down buttons
Indicates
Sets the time of the day at which to start cleaning up the Event Viewer database
in accordance with the 
according to the Events archive length parameterHH:MM:SSCurrent system time at the moment of the object setting panel opening00:00:00 to 23:59:59

2

Events archive length

Type-in

____days

Enter the value

in

into the field

Specifies

Sets the number of days to store information about the events registered by Axxon PSIM and recorded into both the Event Viewer and the Incident server. This parameter affects all computers in a distributed system

Days

3

Not less than 0

3

Object code

Type-in

Enter the value

in

into the field

Defines

Sets the number of the access control card, which is automatically displayed in the

User

settings panel of the User object, when the object is

being

created in the

Facility

Object code field

Sequence of numbers

Not

specified

defined

More than 1

4

Run macro at start

Starting configuration

Select the value

Is selected

from the list

Defines

Sets the macro

command

, which will be automatically launched

with the

at Axxon PSIM

system startup

start

Names of the Macro objects registered in the system

Not

specified

defined

Depends on the number of the Macro objects created in the digital

distributed

video surveillance system with distributed architecture

5

Connections in

the

architecture

Is identified by the check mark

Specifies

Set the checkbox

Sets the computers with which the created Computer object

is to exchange

should exchange the data about the system configuration parameters

data

: with all computers in the digital video surveillance system with distributed architecture or only with the Computer object

under

on the basis of which the given object was created

Boolean type

Not specified

Clear

Setwhen

Yes—when

creating a new computer, the Connection checkboxes in the Architecture tab are set

checked

for all computers in the architecture

.

No—when

Clearwhen creating a new computer, the Connection checkbox in the Architecture tab is set

checked

only for the computer on which this new object is created

.

6

DNS instead of IP allowed

Checkbox

Enables setting

Set the checkbox

Sets the address of the Server/Remote Administrator’s workstation/Remote Client in the Architecture tab as DNS

name—not

name, not only IP address

Boolean type

No

Clear

Set—when configuring the interaction of the computers in the distributed system, DNS

Yes—DNS

name (instead of IP address) of the Server/Remote Administrator’s workstation/Remote Client can be specified in the Architecture tab

when configuring computer interoperability in distributed system. Validation of the specified address is disabled.

Clear—when configuring the interaction of the computers in the distributed system, IP address of the

No—IP address of

Server/Remote Administrator’s workstation/Remote Client

is to

should be specified in the Architecture tab

when configuring computer interoperability in distributed system

7Ping (sec
.
)
Type-in
Enter the value
in
into the field

Sets

Server-computer ping periodNon-negative integer number

the check period for the computer connection to the Server

Sequence of numbers10>=
0
1
8Show documentation by clicking F1Set the checkboxEnables opening documentation in the
.
pdf format by
clicking
pressing F1, when Axxon PSIM is started.
 
Administrator's Guide is opened on the Server and the Remote Administrator’s workstation; Operator's Guide is opened on the Remote ClientBoolean type
No
Clear

Set—the documentation is displayed by pressing F1

Clear—the feature of displaying the documentation by pressing

Yes—documentation is shown by clicking F1.

No—feature of showing documentation by clicking

F1 is disabled

9Debug statisticsClick the buttonOpens the
event
window with the events queue statistics
window
---
10Administrator’s passwordClick the button
Gives
Open a
command to open a
dialog box for
assigning
setting the Administrator’s password---

The Internal synchronization group

11

offline

Checkbox

Set the checkbox

Enables the offline synchronization of the events

Boolean type

Yes

Yes—offline
Set

Set—the offline synchronization is enabled. When the computer is reconnected, it gets all the events for the period when there was no connection

.

No—offline

Clear—the offline synchronization is disabled. When the computer is reconnected, it does not get the events for the period when there was no connection

12

online

Checkbox

Set the checkbox

Enables the online synchronization of the events

Boolean type

Yes

Yes—online
Set

Set—the online synchronization is enabled.

Events

The events are sent right after they

happen

occur according to the configuration parameters of the computer interaction

configuration parameters.

in the distributed system

Clear—the online

No—online

synchronization is disabled.

Events

The events are not sent

The Holidays group

13

Date*

-

List of calendar days which will be defined as holidays in

the

Axxon PSIM

software

Date

Not

specified

defined

Date format: DD-MM-YY

14

Add

Click the button

Opens the Calendar dialog box to set the date of a new holiday

-

-

-

15

Delete

Click the button

Deletes the selected holiday date from the Date list

-

-

-

16

Change

Edit

Click the button

Opens the Calendar dialog box to change the date of the selected holiday

date

in the list

-

-

-

SMS confirmation
17SMS confirmation
Type-in
Enter the value
in
into the field
Defines
Sets the Short
message
Message object for two-factor authentication—see Configuring two-factor authenticationNames of the Short
message
Message objects registered in the systemNot
specified
definedDepends on the number of the Short
message
Message objects created in the system
The RabbitMQ tab
18Server
Type-in
Enter the value
in
into the fieldSets the RabbitMQ host addressLatin characters, digits and service characterslocalhostHost IP address or name
19Port
Type-in
Enter the value
in
into the fieldSets the RabbitMQ host portLatin characters, digits and service charactersNot
specified
defined
0 –

0–65535

If the port is 0 or not

set

specified,

the RabbitMQ client does not

RabbitMQ won't run

20User
Type-in
Enter the value
in
into the fieldSets the RabbitMQ host user nameLatin characters, digits and service charactersguestDepends on the registered RabbitMQ users
21Password
Type-in
Enter the value
in
into the fieldSets the RabbitMQ host user passwordLatin characters, digits and service charactersguestDepends on the registered RabbitMQ users
22Content-typeSelect the value from the listSets the type of
content
the sent/received contentSupported types of content
type
plain/text

application/json—a message in JSON format is sent

/received

plain/text—Axxon PSIM event is sent

/received

in the following format: "TYPE|ID|EVENT"

*The name Name of the element is not isn't displayed in the settings panel of the given object.