The data about events registered in the system is stored in the Protocol table in Axxon PSIM (by default) or in the Protocol table of an individual database (see Extracting event protocol into an individual database).
...
In the Events archive length field field, specify the time period in days for storing the event archive in the Event Viewer database (3). This setting is relevant only for the Server corresponding to the Computer object. To specify the time period for storing the event archive for all Servers in the distributed system, use the common settings in the Programming tab (see The Settings panel of the Security zone object section). The The value of the Events archive length parameter on the settings panel of the Computer object has the higher priority.
| title | Note |
|---|
If no value is specified in the Events archive length field on the
configurationsettings panel of the Computer object, the value specified in the
configurationsettings panel of the Security zone object is used.
| Info | ||
|---|---|---|
| ||
The specified Events archive length is also applied to the events received by the Incident server, which are stored in the PROTOCOL_INC_SERVER table of the Psim database. |
| Info | ||
|---|---|---|
| ||
The process of clearing the database of the events older than the specified storage period is started by default every day at midnight. It deletes 100,000 events every three minutes, starting with the oldest ones. |
| Info | ||
|---|---|---|
| ||
| Steps 1 and 3 are for configuring events viewing in the system with distributed configuration. |
The Event Viewer The events logging to database is now configured.
| Info | ||
|---|---|---|
| ||
| The You can also use the tweaki.exe utility can also be used to configure events viewing logging (see the The Settings panel of the Axxon PSIM section). |
...