The INC_MANAGER object sends events given in the table. Procedure is Procedures are started when the corresponding event appearsoccurs. Format of event procedure for the Incident manager object:
| Code Block |
|---|
OnEvent("INC_MANAGER","_id_","_event_") |
| Events | Event description | Paremeters |
|---|
Description| Parameter description | Comment |
|---|
CLOSE_CLICK | Click the Close button in the interface |
|
| The event is generated when an incident is closed without being processed by the operator in the Incident manager interface |
| CLOSE_ALL_CLICK | Click the Close all button in the interface |
|
| The event is generated when all incidents are closed without being processed by the operator in the Incident manager interface |
SELECT | Click |
on | an incident in the interface |
|
| The event is generated if the operator left-clicks or right-clicks on the incident in the Incident manager interface |
ACTIVATE_EVENT
| The operator selected the event (click the event with the mouse)
| alarm_time<> | Time when the event occurred |
|
| event_guid<> | Event ID (generated randomly for each event) |
|
| objtype<> | Object type (e.g., CAM, GRELE, etc.) |
|
action<> | Action type (e.g., MD_START, DISARM, etc.) |
|