All events registered in the system or those events that match preconfigured filters are displayed in the Event viewer.

Note
titleAttention!

A blank filter (i.e. filter with blank columns) is to be created in order to display all events for all objects in the system in the Event viewer. All events are also displayed in the Event viewer when there is no filter at all (see Configuring event filters for displaying in the Event viewer).

If you delete all previously created filters, an "empty" filter will be left. When selected, it will display all events.

...

The Show filters checkbox opens the list of filters configured while system setup (see Configuring event filters for displaying in the Event viewer). To activate the filter, set the checkbox next to it's name. Several filters can be activated simultaneously. Options for using filters are described in the table:

Filter use optionFilter settings made beforehandResult in Event viewer
Filter checkbox is setCertain objects and their events are selectedOnly events that match the filter are displayed
Several filter checkboxes are setCertain objects and their events are selected in each of the filters

Only events that match at least one of the selected filters are displayed

No filter is selected (all filter checkboxes are clear)Certain objects and their events are selected in each of the filters

Only events that match at least one of all created filters are displayed

"Empty" filter checkbox is setNo object or event is selectedAll events from all system objects are displayed

There are no filters created for the Event viewer in the system, there are no filter checkboxes available

-All events from all system objects are displayed

The selected filters and the filter display settings remain the same after Intellect is restarted, i.e. if certain filters are selected and the list of filters is hidden, then after you restart Intellect, the Event viewer will display events according to the previously selected filters.

...

By default, events are sorted by date and time in the Event viewer window. Events can be sorted by any of the columns. To enable or disable sorting, left-click the header of the required column. In this case, when changing the filters, sorting is saved. When changing the filters, the sorting is saved.

When sorting by time, new events are added to the end of the list in the Event viewer. The list is scrolled in such a way that the last event is always displayed in the box and it is marked. When the event (different from the last one) is marked, the list is fixed and there is no scrolling, new events are added to the end of the list. Scrolling is resumed in the following cases:

...

The Clear button is used to clear the list of events in the Event viewer.

Info
titleNote
After the Event viewer is cleared and if hidden events are to be displayed again, then Intellectis to be should be restarted with the Load protocol checkbox set checked (see Event viewer parameters).

...