The ZK C3-100, ZK C3-200, ZK C3-400 controllers are configured You can configure the ZK Teco C3, C5, InBio controllers on the settings panel of the corresponding objects AC ZK Controller C3 -100controller, AC ZK Controller C3-200 and AC ZK Controller C3-400 which ZK C5 controller and ZK INBIO controller objects that are created on the basis of the AC ZK Teco object on the Hardware tab of the System settings dialog window parent object.
| Info | ||
|---|---|---|
| ||
The configuration of ZK Teco controller controllers will be configured using the ZK C3-100 as an example. Other controllers are configured considered on the example of the C3 controller. You can configure other controllers in the same way. |
To configure the a ZK Teco controllers controller, do the following:
- Go to the settings panel of the corresponding corresponding ZK Teco controller..
- From the Gate drop Interlock drop-down list (1), select the type of controller connection (see Configuring the connection to the ZK Teco controller/elevator control panel or Configuring the connection via RS-485 standard).
- In the Password field (2), enter the password for controller connection.
- If the Ethernet connection type was selected, then enter the IP address of the controller in the IP field (3).
- If the the RS-485 standard connection type was selected, then select the connection COM port number from the Address drop-down list (3).
- a group of interlocked doors. Interlock is a two-cycle mode with a stop to check a person who enters. Interlock can be set for two or more locks belonging to one access controller.
- Disable—doors interlock function is disabled (default).
- Doors 1 and 2—doors 1 and 2 are interlocked.
- Doors 3 and 4—doors 3 and 4 are interlocked.
- Doors 1, 2 and 4—door 1, door 2 is interlocked with door 4.
From the Anti-passback drop-down list (4), select the mode of anti-passback operation:
Mode
Description
Controller
Disable
The anti-passback function is disabled All controllers Readers of Door 1 The anti-passback function is enabled between the readers of Door 1 ZK C3-100, ZK C3-200 Readers of Door 2 The anti-passback function is enabled between the readers of Door 2 ZK C3-200 Readers of door 1, readers of door 2 The anti-passback function is enabled between the readers of Door 1 and Door 2 respectively ZK C3-200 Door 1 and 2 The anti-passback function is enabled between the readers of Door 1 and Door 2 ZK C3-200, ZK C3-400 Doors 3 and 4 The anti-passback function is enabled between the readers of Door 3 and Door 4 ZK C3-400 Doors 1 and 2, doors 3 and 4 The anti-passback function is enabled between the readers of Door 1, Door 2, Door 3 and Door 4 ZK C3-400 Doors 1, 2 and doors 3, 4
The anti-passback is enabled between Door 1, 2 and Door 3, 4 ZK C3-400 Door 1 and doors 2, 3 The anti-passback is enabled between Door 1 and Door 2, 3 ZK C3-400 Door 1 and doors 2, 3, 4 The anti-passback is enabled between Door 1 and Door 2, 3, 4 ZK C3-400 From the Interlock drop-down list (5), select the mode of doors interlocking:
Mode
Description
Controller
Disable
The interlock function is disabled All controllers Door 1 and 2 Doors 1 and 2 are interlocked mutually ZK C3-200, ZK C3-400 Door 3 and 4 Door 3 and door 4 are interlocked mutually ZK C3-400 Doors 1, 2 and 4 Door 1, door 2 and door 4 are interlocked mutually ZK C3-400- Doors 1 and 2, doors 3 and 4
- —door 1 is interlocked with door 2
- ,
- door 3
ZK C3-400 - is interlocked with door 4
- .
- Doors 1, 2, 3 and 4
- —door 1, door 2, door 3
- is interlocked with door 4
ZK C3-400 - .
Info title Note To open one of the
interlocked doors,
other
interlocked doors in the group must
be closed. This means that only one door in a group of
interlocked doors
can be opened at a time.
- From the Backup Reserv. period drop drop-down list (6), in the range from 1 to 24, select the time interval period in minutes for after which the automatic backup of data of the specified type (see Managing the configuration of ZK Teco controllers). Set the Watch dog checkbox (7) to enable the automatic data backupdata will be automatically backed up. The default value is 1.
The Watchdog checkbox is set by default. It enables the watchdog timer. This is a monitoring system that restarts the hardware in time to restore its functionality if a failure occurs. If the microcontroller port does not respond to the timer within a certain time or number of cycles determined in the program, a reset and restart command is sent to the device. To disable the mode, clear the checkbox.
Set the Two doors two directions mode checkbox to enable two-directional access control for two doors.
From the Mode number drop-down list, select the antipassback control mode. By default, this setting is disabled (Disabled). The antipassback control modes depend on the controller type (For details, see the manufacturer's documentation).
Click the Apply button (9).
Info title Note. After a successful connection with the controller is established, the firmware version and the controller serial number general information about the device will automatically be displayed in area (8).
...