Events are processed in the Current events tab tab of the Operator protocol window. The examples The examples of the tab display:
...
The details of event display:
| Info | ||
|---|---|---|
| ||
Temporary images (event events screenshots) are stored in the C:\Users\<User name>\AppData\Local\Temp\OperatorProtocol folder. They are automatically deleted at normal Axxon PSIM shutdown or restart. |
...
On the right there is a checklist of actions that should must be performed during the event processing. This list is set up by the Administrator during the Operator Protocol protocol configuration. After you perform the required action, set the checkbox next to it, and the information about the task completion will be added to the comment field along with the date and time indication.
...
To assign a type to the event, select one or several event cells or lines using the left mouse button (hold down the Ctrl key to select several events, if this feature is enabled in the system settings) and then click one of the buttons on the event control panel. The buttons for event processing may not be available until a comment is entered if the corresponding setting is enabled. If the helping guides were added during the Operator Protocol protocol configuration, you can click the button and open the helping guide about the event processing.
| Info | ||
|---|---|---|
| ||
If the events are grouped, then selecting a line with the with the grouping name will select all events from this grouping. The presence of the event processing buttons depends on the settings of the Operator Protocolprotocol. |
The button names can be changed during the Operator Protocol system configuration stage.
| Info | ||
|---|---|---|
| ||
When you select the event cell or line, the camera (linked to the corresponding object) activation event is generated. If the Active monitor is configured in the system (see Configuring the display mode of camera windows), then video from the corresponding camera is displayed in it. If several cells are selected, then cameras are displayed one-by-one on the Active monitor. |
After the type is assigned to the event, it is removed from the Current events tab in the Operator protocol window. If the event (after being processes) is not removed from other Operator protocols when configuring the Operator protocol (see Setting the options for handling events in the Operator protocol), then the processed event is marked grey in other Operator protocol windows. But other operators can process this event once again.
| Info | ||
|---|---|---|
| ||
If all non-processed events are to be assigned with the type of If all non-processed events must be assigned with the type of the selected event, then set the Apply to all checkbox. |
In order to delay the event processing once for the time period specified when configuring the Operator protocol, click the Delay button. The event will not be removed from the Operator protocol windows and it will not be marked grey in other Operator protocols.
| Info | ||
|---|---|---|
| ||
If the time of waiting for the response from the Operator (specified in the settings of the Operator protocol object) (see Administrator's Guide) is exceeded, then the event is escalated and if the chief interface is not assigned to the Operator protocol, then it is removed from the Current events tab and the Non-processed type is assigned. When Axxon PSIM is restarted, the non-processed events are saved. |
...
If the events are displayed as cells, then the frame of the moment of alarm (screenshot of the event) can be enlarged. To do this, double left-click on it. The window with zoom-in frame appears. This window can be moved around the screen by dragging the title bar with the left mouse button; in this case, the position of the window will be remembered saved for each type of event and window of the Operator Protocol protocol. To close this window, click the X button in the upper right corner or press Esc on the keyboard.
...
If the ActiveX video display method was selected during the Operator Protocol protocol configuration, the window for the video viewing video viewing and exporting will open. The ActiveX The ActiveX window interface is the same as the Video Surveillance Monitor surveillance monitor interface. This window can be moved around the screen by dragging the title bar with the left mouse button; in this case, the position of the window will be remembered saved for each type of event and window of the Operator Protocolprotocol. To close this window, click the X button in the upper right corner or press Esc on the keyboard.
If the Monitor video display method was selected, then the required camera(s) will be displayed on the selected Video Surveillance Monitor in selected monitor in the archive viewing mode. In this case, the current playback position will be set to the position corresponding to the beginning of the video recording. The ArchShift The ArchShift registry key can shift the playback position (see Registry keys reference guide).
To view the object from which the event comes on the interactive Map, select the event cell and click the Find on map button on the control panel. As a result the required layer of the interactive Map is displayed. The corresponding object is highlighted with green dots and marked with concentric black-and-white circles.
...