- Create the required detection tool and specify its parameters (seeConfiguring detection tools detectors and their sub-toolsdetectors).
- Below the created detection tool, click Create… → Multiple Objects.
By default, the detection tool is enabled and triggers set to generate events when the number of objects in the detection area exceeds the value specified in the detection tool settings.
...
| Parameter | Value | Description | |||||
|---|---|---|---|---|---|---|---|
| Other | |||||||
| Enable | Yes | The detection tool is enabled by default. To disable the detection tool, select the No value | |||||
| No | |||||||
| Name | Multiple Objects | Enter the detection tool name or leave the default name | |||||
| Type | Multiple Objects | Name of the detection tool type (non-editable field) | |||||
| Basic settings | |||||||
| Maximum object height | 100 | Specify the maximum object height as a percentage of the frame size for the detection tool to triggergenerate an event. The value must be in the range [0.05, 100]
| |||||
| Maximum object speed | 500 | Specify the maximum object speed per second for the detection tool to trigger generate an event. The value must be in the range [0, 500]
| |||||
| Maximum object width | 100 | Specify the maximum object width as a percentage of the frame size for the detection tool to trigger generate an event. The value must be in the range [0.05, 100]
| |||||
| Minimum object height | 0.1 | Specify the minimum object height as a percentage of the frame size for the detection tool to trigger generate an event. The value must be in the range [0.05, 100]
| |||||
| Minimum object speed | 0 | Specify the minimum object speed per second for the detection tool to trigger generate an event. The value must be in the range [0, 500]
| |||||
| Minimum object width | 0.1 | Specify the minimum object width as a percentage of the frame size for the detection tool to trigger generate an event. The value must be in the range [0.05, 100]
| |||||
| Number of alarm objects | 10 | Specify the number of objects for the detection tool to trigger generate an event. The value must be in the range [1, 100]. | |||||
| Object class | All classes | Select the object class that must trigger the detection tool generate an event. The default value is All classes
| |||||
| Vehicle | |||||||
| Person | |||||||
By default, the entire frame is the detection area. In the preview window, you can specify the detection areas using the anchor points (see Configuring the Detection Zonea detection area).