Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Note
titleAttention!

For detailed information on how to configure DEA FUSION P2P controller, please refer to the FUSION P2P Service Software Manual.

In order to configure minimum required settings which allow communication between DEA FUSION P2P controller panel and and Axxon One, you may do the following:

  1. Install Virtual comport driver, which is used to connect the DEA FUSION P2P controller to the computer via USB port.
  2. Connect DEA FUSION P2P controller to the computer via USB port.
  3. Open FusionLightService.exe.
    Login window will appear. 

    Image Modified
    ParameterDefault value
    Usernameinstallatore
    Passworddea
  4. Go to Options.
    Image Modified
  5. Go to Serial port. Select the device which is to be configured from the list, and then press OK.
    Image Modified
  6. Go to Board connection. For the Type of connection, select USB Port, and then press OK.
    Image Modified
  7. Fill in the password and press OK.
    Image Modified
    Controller configuration interface will be displayed.
    Image Modified
  8. Go to Configuration.
    Image Modified
  9. In the Clients DeaMap.dll / SC-DN-ETHSRV parameters tab, configure the following settings:
    Image Modified
    1. In the Name field, specify name for the account.
    2. In the Address field, specify the IP address of the Axxon One server on which the DEA Security Fusion P2P integration module will run.
    3. In the Password field, specify a secure password.
    4. In the Port field, specify the port which is to be used to establish the connection for the user.
    5. For the Receives, Modify and TCP fields, set the value to 1.
      Info
      titleNote

      The values of the NamePassword and Port parameters will be necessary to configure Dea Security Root object of the DEA Security Fusion P2P integration module in Axxon One.

  10. Go to Network tab and configure network settings.
    Image Modified
    1. In the Local parameter group, configure network settings of the DEA FUSION P2P controller.
      Info
      titleNote

      It is recommended to configure static IP address.

    2. In the DeaMap.dll board parameters group, set up an unique Name, Port, and Password.
    3. Press the OK button.
      Info
      titleNote

      The values of Ip Add, Name, Port and Password parameters will be necessary to configure Fusion P2P Controller object of the DEA Security Fusion P2P integration module in Axxon One