titleAttention!

For detailed information on how to configure the DEA FUSION P2P controller, please refer to the FUSION P2P Service Software Manual.

In order to configure minimum required settings, which allow communication between the DEA FUSION P2P controller panel and Axxon One, you may do the following:

  1. Install Virtual comport driver, which is used to connect the DEA FUSION P2P controller to the computer via a USB port.
  2. Connect the DEA FUSION P2P controller to the computer via a USB port.
  3. Open FusionLightService.exe.
    Login window will appearopens


    ParameterDefault value
    Usernameinstallatore
    Passworddea
  4. Go to Options.
  5. Go to Serial port. Select the device, which is to must be configured, from the list, and then press click the OK button.
  6. Go to Board connection. For the Type of connection, select USB Port, and then press click the OK button.
  7. Fill in the password and press click the OK button.

    Controller configuration interface will be displayed.
  8. Go to Configuration.
  9. In the Clients DeaMap.dll / SC-DN-ETHSRV parameters tab, configure the following settings:

    1. In the Name field, specify name for the account.
    2. In the Address field, specify the IP address of the Axxon One server on which the DEA Security Fusion P2P integration module will run.
    3. In the Password field, specify a secure password.
    4. In the Port field, specify the port, which is to must be used to establish the connection for the user.
    5. For the In the Receives, Modify and TCP fields, set the value to 1.
      Info
      titleNote

      The values of the NamePassword and Port parameters will be necessary to configure configure the Dea Security Root object of the DEA Security Fusion P2P integration module in Axxon One.

  10. Go to Network tab and configure network settings.
    1. In the Local parameter group, configure network settings of the DEA FUSION P2P controller.
      Info
      titleNote

      It is recommended to configure static IP address.

    2. In the DeaMap.dll board parameters group, set up an a unique Name, Port, and Password.
    3. Press Click the OK button.
      Info
      titleNote

      The values of the Ip Add, Name, Port and Password parameters will be necessary to configure the Fusion P2P Controller object of the DEA Security Fusion P2P integration module in Axxon One

...