Go to documentation repository
...
| Info | ||
|---|---|---|
| ||
The Computer object must correspond to the Axxon PSIM server that is selected for integration. |
...
| Field | Description | Default value |
|---|---|---|
| Address | IP address | 127.0.0.1 |
| Port | Port for communication with client (NativeBL port) | 20109 |
| Base port | Port for operations within a domain | 20111 |
| Web port | Web Server port (HTTP port for failover server) | 80 |
| Login | Axxon One username | root |
| Password | Axxon One password | root |
| Info | ||
|---|---|---|
| ||
The connection ports depend on the type of Axxon One installation (failover or not) and its settings. For more information, see the Axxon One documentation: |
| Note | ||
|---|---|---|
| ||
Specifics of synchronization with Axxon One using the Update button:
|
The result of the synchronization is displayed in the information fields Last successful synchronization and Last synchronization state. If the synchronization was successful, the hardware received from Axxon One appears in the hardware list, and the received macros appear in the Macros list on the Programming tab.
In the Path field, specify the path to the previously installed Axxon One client (see Pre-configuration Preconfiguration of Axxon One) that will be used to launch the Axxon One Monitor interface object. The default path is: C:\Program Files\AxxonSoft\AxxonOne\bin\AxxonOne.exe.
| Note | ||
|---|---|---|
| ||
Note that this path must be the same on all computers where you want to run the Axxon One client (AxxonOne.exe). This means that the Axxon One client must be pre-installed in the same folder on all computers. |
...