Go to documentation repository
| Note | ||
|---|---|---|
| ||
By default, the Program object isn't displayed on the Programming tab. It is designed |
...
to create specialized programs in the embedded programming environment of Axxon PSIM. To display the object, specify the OldScript=1 parameter of the HKEY_LOCAL_MACHINE\SOFTWARE\AxxonSoft\PSIM\ registry key (see Registry keys reference guide) or use the tweaki.exe utility by setting the Old scripts support checkbox (see point 19 on the page The Settings panel of the Axxon PSIM section). |
The settings panel of the Program object is shown in the figure.
Table The table describes the setting parameters corresponding to the elements of the settings panel of the Program object.
№
| Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Program object in the video surveillance system | Numbers, letters, periods, hyphen, dash, and underscore | -NA | Depends on the number of the Program objects in the digital video surveillance system with distributed architecture |
2 | Name* | Enter the value into in the field | Sets the name of the Program object | Latin, Cyrillic, digits and service characters | Program | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Sets the state (enabled or disabled) of the Disables the Program object | Boolean type | Clear | Set—the Program object is disabled and isn't used Clear—the Program object is enabled and used |
4 | Time schedule | Select the value from the list | Sets the time period during which the given program operates | Names Name of the Time schedule registered in the system | Never | Never—this program will never be isn't executed Always—this program is always in the state of executionexecuted List of the created time schedules—the program will be is executed within a pre-defined the time period specified in the time schedule |
The Computers group | ||||||
5 | Select an element | Set the checkbox | Sets the computer on which the given program will be is executed | Boolean type | Clear | Set—the program will be is executed on the specified computer Clear—the program will not be isn't executed on the specified computer |
6 | Computer | Automatically | Sets the name of the computer in the local network | Computer name in the local network | Computer name in the local network | A line containing a sequence of any characters (letters, digits, service characters), case-insensitive. Number of characters—60 |
7 | Name | Automatically | Sets the name of the computer | Name of the Computer object registered in the system | Name of the Computer object registered in the system | A line containing a sequence of any characters (letters, digits, service characters), case-insensitive. Number of characters—60 |
| Not in a Out of the group | ||||||
8 | Filter | Enter the value into in the field | Used Sets to pre-filter events processed by the program | Latin, Cyrillic, digits, and service characters, and digits | Not definedNA | A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive. Number of characters—unlimited. Filter The filter format is TYPE|ID|EVENT divided by semicolon. For example, the CAM||MD_STOP;CAM||MD_START to filterformat filters Alarm and Alarm end events from all Camera objects |
9 | Text editor | Enter the value into in the field | Used to enter Enters the text of the executed program that must be executed | Latin, Cyrillic, digits, and service characters, digits | Not definedNA | A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive. Number of characters—unlimited |
* Name of the object isn't displayed on the settings panel.