Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range


1

DecompressorSelect the value from the list

Sets the technology using which the compressed video stream is decompressed when displaying the video signal on the monitor

Note. By default the parameter is not available for editing. To change the value of this parameter, set the 1 value for the EnableCodecSettings registry key (see Registry keys reference guide)

List of available decompressorsNo
  • BOSCH;
  • FfmpegAllInOneDecoder;
  • H263IppDecoder;
  • H264InterlacedIppDecoder;
  • H264IppDecoder;
  • MJPEGIpp;
  • Motion Wavelet 3.5;
  • Motion Wavelet 7.1;
  • MPEG2IppDecoder;
  • MPEG4IppDecoder;
  • MxPEG Mobotix;
  • RGB24toYUV420;
  • StreamLabs;
  • VWV;
  • WMVIppDecoder

2

Compressor 

Select the value from the list

Sets the algorithm of the video stream compression 

Note. By default the parameter is not available for editing. To change the value of this parameter, set the 1 value for the EnableCodecSettings registry key (see Registry keys reference guide)

List of available algorithms

No

Depends on the camera model

3

Estimate motion

Enter the value in the field

Sets the threshold of the camera sensitivity to motion depending on the change of the object brightness. The delta frame of the video signal is formed according to this criterion

Sequence of numbers

7

From 2 to 255

4

Key frames interval

Enter the value in the field

Sets the rate of the key frames

Sequence of numbers

8

Depends on the capabilities of the camera

Out of the group

5Additional infoEnter the value in the fieldSets the information displayed on the video surveillance monitor above the camera name. This information is added to the export file, and when the frame is printed, to the event logLine not longer than 100 charactersBlank lineLatin and Cyrillic letters, digits

6

Rotation mode

Set the checkbox

Enables the rotation of the video image displayed on the Video surveillance monitor 

Boolean type

Clear

Set—rotation is enabled

Clearrotation is disabled

7

Rotate on*

Select the value from the list

Specifies the angle of video image rotation when the rotation mode is enabled

Sequence of numbers

0

0, 90, 180, 270

The Priority group
8

Processing priority

Set the slider in the required position

Sets the priority of the video signals processing by ADC

Order of video signals processing

Normal

  • Normalnormal video signals processing order;
  • 1/31/3 processing order;
  • 1/21/2 processing order
9

Recording priority

Set the slider in the required position

Set the priority of video signals processing by ADC in the recording mode

Order of video signals processing in the recording mode

Normal

  • Normalnormal video record order;
  • 1/31/3 processing order;
  • 1/21/2 processing order;
  • Real timeall ADC resources are used for video signals recording
The Store no less than group

10

Store no less than

Enter the value in the field

Sets the time period for keeping the video archive and audio archive from the camera (in case of synchronous recording) on the server. The parameter allows storing the large archive for the selected camera using the archive of other cameras.

Note. We recommend setting the Store no less than parameter for no more than 30% of cameras in the system, as this setting is only ADVISORY. If there isn't enough space for the archive recording, the setting is ignored and the recording doesn't stop anyway.

If you create more than 10 cameras in the system, then when attempting to set this parameter for more than 30% of the cameras in the system, after you click the Apply button, a corresponding warning message appears. You can disable it using the NotifyAbout_arch_days registry key (see Registry keys reference guide)

Day or hour, depending on the value selected in the drop-down list

NA

More than 1

11Store no less thanSelect the value from the listSets the units for the time period specified in the Store no less than fieldList of available time unitsDays

Days

Hours

The Store no more than group
12Store no more thanEnter the value in the field

Sets the time period for storing the camera archive, after which the camera archive must be deleted

Note. The archive can be deleted before the specified time if it is required for loop recording

Day or hour, depending on the value selected in the drop-down listNAMore than 1
13Store no more thanSelect the value from the listSets the units for the time period specified in the Store no more than fieldList of available time unitsDays

Days

Hours

The Fisheye group
14Lens type

Select the value from the list

Sets the used lens typeSupported lens typesNo
  • No—select if there are neither fisheye nor panomorph lenses on the camera;
  • Standard fisheye lens—select if there is a fisheye lens on the camera;
  • Autocalibration—select if there is a fisheye lens on the camera and it is necessary to determine the video conversion parameters automatically for artifact elimination;
  • A0*V, A1UST, A8TRT, B0QQV, B4QQV, B5SST, B6SSTtypes of panomorph lenses
15Camera position

Select the value from the list

Sets the position of the cameraSupported camera position optionsCeiling
  • Ceiling;
  • Wall;
  • Floor
16Visible partEnter the value in the field

Determines which part of the frame is visible on the Video surveillance monitor after the conversion

Percentage

75% for the Ceiling position

66% for the Wall position

Note. The default value may not appear in the field

From 0 to 100

...