Go to documentation repository
To set the event parameters of the Event viewer parameters, do the following:
From If it is necessary to display only one latest event or all latest events in Event Viewer interface box, select One latest or All events in the View events: drop-down list (2), select: all events, one latest, all last.
| Info | ||
|---|---|---|
| ||
| If All events item is selected and the event is repeated for the object, there is time changing of present event recording and a new recording line is not created. | ||
When you select all last, if the object has a repeating event, the time of the existing event record is changed, and a new line isn't created in the Event viewer window. By default, | ||
| Info | ||
| ||
| By default all events are displayed in the Event Viewer interface boxviewer window. |
In the View days text field (3), specify the time period ( in days ) over which the events are to must be displayed in the Event Viewer viewer interface window if there are more events than the than the number set in the Max.number of rows field (34). If there are less fewer events than set in the Max.number of rows field, in the Event Viewer, events will be displayed for all days are displayed, regardless of this setting. And the events Events are excluded from being displayed until their number becomes equal to the value in the Max.number of rows value field. Verification of the fulfillment of this condition and exclusion of events from being displayed happens occurs every 50 events.
Set the Load protocol checkbox (8) to load If the last 1000 logged events are to be displayed registered in the Event Viewer interface box, then set the Load protocol checkbox (8)viewer object to the Event viewer window when you start Axxon PSIM.
| Info | ||
|---|---|---|
| ||
When the Load protocol checkbox is set, the events of those objects that have been deleted without giving aspecifying the source (the name of a deleted object is not displayed) can be displayed. Such operation of thethe Event Viewerviewer allows for the extra control over system objects. | ||
| Info | ||
| ||
| A thousand of last events for each object or each object type is loaded when If the filter of the Event viewer is configured to display events from several objects or several types of objects, then if the Load protocol checkbox is set if the filter of Event log is configured for displaying events from several objects or several object types, the last 1000 events for each object or each type of object are loaded. For example, if the Event log is receivingviewer receives events from the Camera 1 object and fromall MacrosMacro objects, a thousand ofthen 1000 events from the Camera 1 object and a thousand of1000 events from Macrosthe Macro objects will beare loaded. |
Set the Hide Region checkbox checked if there is no need to show (9) if you don't want to display the Region column in the Event viewer (9).
Set the Hide Card checkbox checked if there is no need to show (10) if you don't want to display the Card column in the Event viewer (10). This column is in use for displaying the used to display the number of an access card number for events coming from ACS integration modules included in the ACFA PSIM PSIM subsystem. See Displaying card number for access events in the Event viewer section in Introduction into the Guide for configuring and working with the Access Manager integration module.
| Info | ||
|---|---|---|
| ||
The card code is saved in the PROTOCOL table in the param1 the param1 field of the event associated with access (for instanceexample, ACCESS_IN). |
The parameters of the Event viewer parameters are now set.