Go to documentation repository
Page History
| Section | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
New integrations and supported devices
AxACFA integrations
All integrations made via the AxACFA feature are universally licensed. This means that licenses are purchased for the system hardware as a whole, not for specific models/vendors. All ACS integrations are licensed per one ACS reader, all FSA integrations are licensed per one addressable sensor or loop (for non-address systems), all PID integrations are licensed per one extended sensor (cable or alarm notification device).
New AxACFA integrations
Modbus Slave, service module, обеспечивающий передачу событий и значений регистров для опроса внешнего Modbus master. Поддержано получение событий и команд по протоколам Modbus TCP или Modbus RTU. Поддержанный тип регистров - Holding Register. Реализованы команды Set Value и Get Value регистра.
New features and improvements
AxACFA modules
Integration modules
- ZK Teko: исправлено получение событий от контроллера
- MORPHO: был изменён механизм чтения журнала. Добавлен параметр Auto Clear Log, который автоматически очищает журнал устройства, когда он близок к полному заполнению. Также добавлена кнопка Clear Log – очищение журнала
- Virdi: стабилизирована выгрузка конфигурации
- Apollo: исправлено окончание временных уровней доступа
Bug fixes
Fixed some errors in the ACS, FSA, PID modules. Improved the stability and performance of the system.
...