Axxon PSIM supports supports automatic video recording upon alarm events registration for each Camera system object individually. By default, the auto-recording option is enabled for all cameras registered in the Hardware tab.

You can disable the auto-recording option upon alarms for each camera individually as well.

To disable the auto-recording upon alarm option event registration for a selected camera, do the following:

  1. Go to the Hardware tab in the System settings window.
  2. Select the Camera object in the object tree that corresponds to the required adjusted camera.
  3. Go to Select the Basic settings tab on the settings panel of the Camera object.
    Image Modified
  4. Clear the Record alarms checkbox.From the Video archive drop-down list, select the Manually value. 
  5. Click the Apply button.

Disabling automatic recording upon alarm event registration for a selected camera is complete.

Info
titleNote
To re-enable the auto recording option upon alarm event registration, repeat the above steps and set select the Record alarms checkbox On alarms value from the Video archive drop-down list.
Tip

Events recordingRecording of events