The To configure the Fire detection and Smoke detection modules are configured similarly and as follows program modules, do the following:
| Info | ||
|---|---|---|
| ||
The If you set the Track alarm end checkbox, the events about the end of fire/smoke are received after the time specified in the the Alarm duration, sec parameter has expired. During this time, all repeated fire/smoke alarm events are ignored. A setting. If, until the end of this period, the current fire/smoke is completed and the new one is detected, the detector doesn't generate events about completing the current and starting the new alarm. The new fire/smoke event is received after the current alarm has is completed. |
In the Detection sensitivity [0, 100] field, enter the detector sensitivity of the detector—an integer value in the range from 0 to 100. This parameter determines at what certainty of fire/smoke detection the detector will generate generates an alarm: the higher the sensitivity, the higher the recognition threshold. For example, at sensitivity 100, the detector neural network must get 100% certainty for some period of time when during the frame processing the frames. The value of the Detection sensitivity field is determined experimentally.
In the Number of frames for analysis and output [5, 20] field, enter the minimum number of frames in the range from 5 to 20 for the detector to analyze before generating an alarm. The higher the value, the more reliable the result of the detector operation. At the same time, if the value is too high, the short-time fire/smoke can be missed. If you enter a value less than the minimum, the value is set to 5.
Set the Scanning mode checkbox to track small objects. If you enable this mode, the load on the system increases. So That is why we recommend specifying a setting the small number of frames processed per second in the Frames processed per second [0.016, 100] field. step 7. By default, the checkbox is clearcleared. For more information on the scanning mode, see Configuring the Scanning mode.
| Info | ||
|---|---|---|
| ||
You cannot configure the scanning windows for the Fire detection and Smoke detection program modules. The default parameters are used. When you use the scanning mode, we recommend using a full frame without specifying the area of interest in step 11. |
| Note | ||
|---|---|---|
| ||
We recommend using the GPU. It can take several minutes to launch the algorithm on the NVIDIA GPU after you apply the settings. You can use caching to speed up future launches (see Optimizing the operation of neural analytics on GPU). |
On the captured video imageframe, sequentially set the anchor points of the area using the left mouse button, the situation in of which you want to analyze, by sequentially clicking the left mouse button. After you add an the area, the rest remaining part of the video image is darkened. If you don't specify the area of interest, the entire frame is analyzed.
Click the OK button.
| Info | ||
|---|---|---|
| ||
To remove the area, click the button next to the Area of interest button. You can add only one area. If you try to add athe second area, the first area will beis deleted. |
Configuring the Fire detection and Smoke detection modules program modules is complete.