This page describes how to configure set the parameters of the Monitor interface window:

  1. screen Screen coordinates and window size;.
  2. toolbar Toolbar (displayed only in the List mode—see Configuring the display mode of camera windows);.
  3. displaying The display of the number, name, time, menu, camera frame, and additional info information in the Surveillance surveillance windows displayed on the Video video surveillance monitor;.
  4. The ability to select possibility of selecting cameras that you want to be displayed in the Surveillance window using a display in the surveillance window using the special menu in which cameras are grouped, and you can use a search.

To set the parameters of the Monitor interface window, do The setup is performed in the following way:

  1. Go to the Basic settings tab on the settings panel of the Monitor interface object.
  2. In From the Monitor drop-down listlist (1), select the monitor number in the operating system (computer monitor), the coordinates for which must be set further (1).
  3. Set the position of the Monitor interface monitor window in one of the following ways:
    1. Manually:
      1. Set the coordinates of the left upper corner of the Monitor interface window: the X (the horizontal indent from the left edge border of the image) and Y (the vertical indent from the upper edge border of the image) fields fields (2). Coordinates are set in expressed as a percentage relative to the screen size horizontally and vertically correspondingly, respectively.

      2. Set the size of the Monitor interface window: the W (window’s window width) and H (window’s window height) fields (3). Sizes are set in Dimensions are expressed as a percentage relative to the screen size horizontally and vertically correspondingly, respectively.

        To display a the toolbar in the Monitor  interface window, you must set the switch to the List position on the Basic settings tab and then set the Control panel checkbox (5).

        Info
        titleNote

        If the toolbar is onenabled, the window’s height  H window height is automatically equal to the window’s W window width W. You cannot set a the width less than 20%. Such a setting will be is saved , but it wonisn't be applied.

        Info
        titleNote

        By manually setting the coordinates, you can adjust the position of the Monitor the Monitor interface window on several monitors at the same time. This You can be used use it when setting up a videowallthe video wall. For example, if it is necessary you want to stretch one one Monitor window to two computer monitors, set you must set X=0, Y=0, W=200, H=100. If it is necessary you want to stretch one Monitor window to four computer monitors, set X=0, Y=0, W=200, H=200. 

        Note that if there is one computer monitor, and X and Y coordinates are greater than 100 or width and height are greater than 100, the Monitor window will not be window isn't displayed on this single one monitor or will be is displayed incompletely. 

        Note
        titleAttention!

        When configuring videowall you set up the video wall using Windows means, note that the load on video cards to which the physical monitors for videowall the video wall are connected will be is distributed unevenly, and you cannot be regulated regulate it by using Axxon PSIM means.

        For an even load distribution on the CPU and GPU, you must configure videowall using set up the video wall with the NVIDIA® Mosaic™ technology andusing the NVIDIA® Quadro® Sync device (see NVIDIA documentation).

    2. Using a the test window:
      1. Click the X Image Added button (4).
      2. Place the opened test window Specify dimensions in a test window in the position where the Monitor window must be displayed:
        Image Modified
      3. Click the OK button. As a result, the coordinates in the X, Y, W, H fields will be are set in accordance with the size and position of the test window.
  4. If you want to move the Monitor interface window, set the the Allow moving checkbox (6).

    Info
    titleNote
    This setting is relevant only when you use the toolbar is used.
  5. In the horizontal and vertical fields of the Quad splitter group (7), enter set the number of Surveillance windows which will be surveillance windows that are displayed in the Video surveillance monitor in horizontal and vertical directions correspondingly (7). If window horizontally and vertically, respectively. If you don't set one of these values isn't specified, then the default grid of Surveillance of surveillance windows, depending on the selected layout, is displayed on in the Video surveillance monitormonitor window. The maximum number of Surveillance surveillance windows vertically and horizontally is 64 and 64, respectively.
    If you create several layouts, use the CycleByLayouts=1 parameter of the HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\AxxonSoft\PSIM\ registry key (see Registry keys reference guide) to enable the layouts slideshow.

    Info
    titleNote

    Fields in the Quad splitter group are inactive if the you select the Alarm cameras mode is selected (see see Configuring the display mode of camera windows).

    The Quad quad splitter settings will be are ignored if the CycleByLayouts=1 key is set, which enables paging through layouts (see Registry keys reference guide)user is on the previously created layout.

  6. If you want to save the ratio of the width and height of the video coming from the camera when displaying it is displayed in the Surveillance surveillance window, then set the the Keep camera ratio checkbox (8). If you set the checkbox is set, there may can be some an empty space in the Surveillance windowsurveillance window that isn't occupied by the video during the display. If you clear the checkbox is clear, the video fits the entire area occupies all available space of the Surveillance surveillance window, while the ratio may can be affected.

    Info
    titleNote

    When you work with widescreen monitors, portrait-oriented monitors, or in other cases, it may be necessary to use other window proportions. For this, use the Monitor<monitor_id>_cw, monitor<monitor_id>_ch, monitor<monitor_id>_w43, monitor<monitor_id>_h43 registry keys (see Registry keys reference guide).

  7. Set the Smoothing checkbox (9) to display the video with greater of great resolution on which the ladder effect appears when displaying it is displayed in the small window (9).

    Info
    titleNote

    When using you use the smoothing function, the load on the CPU of the computer where the video is displayed increases significantly (up to 30%). As a result, if the computer does not have enough lacks the resources to use this function, the video display speed (FPS) decreasescan decrease, the response to telemetry commands slows down, and so on. So, Due to this, we recommend using this setting is recommended only for displaying video from analog cameras or the low-resolution video. The function affects only displaying the video display in the Video video surveillance monitor. The original video stream from the camera is streamed comes to the archive and to detection toolsdetectors.

    Video The example of the video image received with the smoothing function

    Video The example of the video image received without the smoothing function

  8. By default, all elements of the Surveillance surveillance window (, such as number, name, time, menu and , camera frame, and the name of the Video video surveillance monitor) , are displayed except for the additional info information (see Additional information on camera). To disable displaying the display of these elements, set clear the corresponding checkboxes clear in the group group 10.

    Info
    titleNote

    The date can be displayed on the video You can also enable the display of the date next to the camera time if using the ShowDate registry key is set.

  9. In the Surveillance surveillance window, you can switch between Cameras cameras using the Camera submenu (see Selecting camera to display in Surveillance window). To have cameras grouped by Computer Set the Select camera with grouping and search checkbox (11) to group cameras in this menu by computers so that you can search among them, set the Select cameras with grouping and search checkbox (11).
  10. To save the changes, click the Apply button (12).

The Setting the parameters of the Monitor interface window are now setis complete.

Tip

Additional information on camera

Video surveillance monitor

...