Go to documentation repository
To provide the effective and steady stable performance of the of Axxon PSIM system, take into account the following recommendations on using the database use below:
Store the Configuration database on the MS SQL server. If the MS Access is used to store the database, it is strongly recommended to install the MS SQL server and to convert the database from MS Access to MS SQL format (see Connecting the Axxon PSIM database)You must synchronize the databases of servers and Remote Administrator Workstations with the administration server database to provide the ability of the centralized administering of the video surveillance and audio control system.
| Info | ||
|---|---|---|
| ||
It is recommended to configure We recommend configuring the automatic backup of the Axxon PSIM database in MS SQL Server, for example, once a week (by default, the automatic backup is not isn't configured). |
In case the Dynamic Host Configuration Protocol If you use the protocol of the dynamic host configuration (DHCP) is used, make sure that the TCP/IP protocol priority for local databases is the highest. Otherwise, when if you disconnect the network cable is disconnected, the communication between the between Axxon PSIM and its local database located on the same computer where Axxon PSIM is is installed can be lost. To view and prioritize the network protocols, use the the SQL Server Configuration Manager utility:
Run the SQL Server Configuration Manager utility (Start → Microsoft SQL Server Express 2014 → Configuration Tools).
In the left part of the utility's interface window, click the header title of the the SQL Native Client Configuration list, and then select the Client Protocols item in the drop-down list. In the right part of the window, right-click any protocol in the list and select the Order item in the context menu that appears.
...