Monitoring PSIM

Registry section

String parameter

Available values

Default

Product version

Description

x32: (x32-Monitoring)

x64: (x64-Monitoring)

LPRDBsearchresultUnicodeBase64

0, 1

1

1.0 and later 

The key sets how to process message in param0<> for the SEARCH_RESULT event of the LPRDB ("External database") object – as ANSI line or Unicode line additionally encoded in base64.

0 – ANSI

1 – UnicodeBase64

x32: (x32-Monitoring)

x64: (x64-Monitoring)

PeakWorkingSetSizeQuota

>=0

100

1.0 and later


The maximum memory size in megabytes used by the process videosrv.exe on Agent Of Control. If the parameter is set to 0, then the check for the used memory is not performed.

Once a day, the Agent Of Control checks the size of the memory it uses. The check is performed at the time specified by the TimeOfCheckWorkingSetSize key (see below).

After exceeding the specified value, the videosrv.exe module is rebooted.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

TimeOfCheckWorkingSetSize

>=0

3

1.0 and later

Time to check memory usage in hours. Default value is 3 (3:00 AM). See also the PeakWorkingSetSizeQuota key description above.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

StoreVideoFiles

>0

3

1.0 and later

Time period for storage of not completely downloaded files on Agent Of Control. After the storage period is exceeded, the not completely downloaded files are deleted.


x32: (x32-Monitoring)

x64: (x64-Monitoring)


run_core


0.1


1

1.0 and later

The key sets the Agent Of Control actions in case if the Axxon PSIM software is shut down.

0 – do not start the Axxon PSIM software

1 – start the Axxon PSIM software




x32: (x32-Monitoring)

x64: (x64-Monitoring)




socket_connect_tout




>=0




0

1.0 and later

The key defines TCP/IP connection mode with Server Of Control.

0 – blocking mode. Agent Of Control connects to Server Of Control without specifying connection timeout.

>0 – non-blocking mode.  Agent Of Control connects to  Server Of Control with a connection timeout set by the socket_connect_tout > 0 parameter in seconds.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

write_buffer_enable

0.1

1

1.0 and later

Data buffering while recording on disc when receiving video data on Server Of Control.  Agent Of Control transfers video data to Server Of Control in packages of 800 to 4096 bytes (4096 by default). When buffering is enabled, a 264 Kb block of memory is allocated to the Server Of Control for receiving video data, and data is saved to the disk when this memory block is full, not every time a packet is received from Agent Of Control.

0 – buffering is enabled.

1 – buffering is disabled.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

stop_data_by_trx

0.1

1

1.0 and later

The key determines the actions of Agent Of Control in case if, during the transfer of video data to ATM PSIM ARM, a financial transaction has begun on the ATM PSIM.

0 – video data transfer is not stopped.

1 – video data transfer is suspended until financial transaction if completed.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

IPPort> 077551.0 and later

The key specifies the port on the Server Of Control/Central Server Of Control used for connecting the clients.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

financial_trx_tout

>0

60

1.0 and later

Timeout for waiting for the financial transaction to complete in minutes. If after the start of the financial transaction during the time-out, there is no message from the ATM about its end, it will be considered to be completed.

x32: HKLM\SOFTWARE\BitSoft\VHOST\ULPR

x64: HKLM\SOFTWARE\Wow6432Node\BitSoft\VHOST\ULPR

ULPRspecialProcessing>=0NA1.0 and later

The key enables special operation mode of the Monitoring PSIM software joint with Auto PSIM.

1 – the special operation mode of the Monitoring software joint with Auto PSIM is enabled.

Any other value – the special operation mode is disabled.

Note. The key is created both on Agent Of Control and Server Of Control.

x32: HKLM\SOFTWARE\BitSoft\VHOST\ULPR

x64: HKLM\SOFTWARE\Wow6432Node\BitSoft\VHOST\ULPR

PlaceOfRecognitionN1,2NA1.0 and later

This parameter corresponds to the point of recognition. PlaceOfRecognitionN, where N is the ID of the LPR channel object.

1 – entrance.

2 – exit.

Note 1. The key is in use in special operation mode of the Monitoring PSIM software joint with Auto PSIM.

Note 2. The key is created at Agent Of Control

x32: HKLM\SOFTWARE\BitSoft\VHOST\ULPR

x64: HKLM\SOFTWARE\Wow6432Node\BitSoft\VHOST\ULPR

CamOfRecognitionN>0NA1.0 and later

This parameter corresponds to the ID of a camera added to the recognition module. CamOfRecognitionN, where N is the ID of the LPR channel object. 

The value of this parameter corresponds to the Camera object ID specified in the LPR channel object settings.

Note 1. The key is in use in special operation mode of the Monitoring PSIM software joint with Auto PSIM.

Note 2. The key is created at Agent Of Control

x32: HKLM\SOFTWARE\BitSoft\VHOST\ULPR

x64: HKLM\SOFTWARE\Wow6432Node\BitSoft\VHOST\ULPR

AlarmMsgOne>=0NA1.0 and later

The key enables the LP found in the database alarm both for Entrance and Exit recognition points.

0 – enables the LP found in the database alarm both for Entrance and Exit recognition points.

Any other value – the LP found in the database alarm is generated for Entrance recognition point only.

Note 1. The key is in use in special operation mode of the Monitoring software joint with Auto PSIM.

Note 2. The key is created at Server Of Control

x32: (x32-Monitoring)

x64: (x64-onitoring)

TimeAlarmFromAgent0, 101.0 and later

The key enables registration of the alarm with the time it occurred on the site.

0 – In the Alarm date field in the interface objects, the time of loading the alarm into the database after it is received from the Agent Of Control is shown, not the time of occurrence of the alarm on site.

1 - In the Alarm date field in the interface objects, the time of alarm occurrence on site is shown.

Note. The key is set on the Server Of Control.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

FileQueryEnable   


0, 101.0 and later

The key enables automated video clip loading.

0 – automated video clip loading is disabled.

1 – automated video clip loading is enabled.

Note. The key is created at Server Of Control and/or Additional Workstation

x32: (x32-Monitoring)

x64: (x64-Monitoring)

FileQueryPath


TextC:\Query\1.0.0 and later

The key sets folder to share data with third party systems which is necessary for automated video clip loading.

Note. The key is created at Server Of Control and/or Additional Workstation

x32: (x32-Monitoring)

x64: (x64-Monitoring)

OldLogPanel0, 101.0 and later

The key changes the Log Panel interface color theme.

0 - dark interface theme.

1 - light interface theme.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

StreamViewerExportPathText<Axxon PSIM installation directory>\export1.0 and later

The key specifies the path to the catalog of frames and video clips which were exported from the Monitoring PSIM interface during the live and archive video playback from a certain camera.

See Playing back live video and archive from a specific camera.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

MonitoringReserving0, 101.0 and later

The key removes the restriction on adding the same cameras for tracking in different Partitions Of Control.

0 - the restriction is enabled.

1 - the restriction is removed.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

AccessByCardEnable0, 101.0 and later

The key activates the special  mode of Monitoring PSIM operation together with ACFA PSIM, as well as the ability to customize the long alarm description.

0 - Special operation mode is off.

1 - Special operation mode is on.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

CustomisedLongAlarmNameTextObject disarmed1.0 and later

The key changes the description of the long alarm Object disarmed in the Monitoring and Monitoring reports interface objects.

x32: HKLM\SOFTWARE\BitSoft\MonitorSSTV\Loader

x64: HKLM\SOFTWARE\Wow6432Node\BitSoft\MonitorSSTV\Loader

UseBulkInsert0, 1
1.0 and later

The key accelerates the speed of data loading from files to the MonitorSSTV database by activating the group operator of data loading if the database is installed locally.

0 - do not use the BULK INSERT operator (if the SQL Server is remote)
1 - use the BULK INSERT operator (if the SQL Server is local)

x32: (x32-Monitoring)

x64: (x64-Monitoring)

PostfixForTimeOutTextNA1.0 and laterThe key specifies the postfix in the identifier of the Partitions Of Control for which the waiting timeout specified in the TimeoutForPostfix key should be specified.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

TimeoutForPostfix


>061.0 and laterThe key sets the waiting timeout in minutes for the Server Of Control to receive the packets with the technical state of Agent Of Control. After this time the "No connection" error will be displayed.
HKEY_CURRENT_USER\SOFTWARE\BitSoft\MonitorSSTVMAXRECORDSONPAGE1,000 - 2,000,000,00010,0001.0 and laterSets the maximum number of events to be displayed in the Event Log window without navigation buttons.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

PassiveModeForFTP 0, 111.0 and later

The key sets the operation mode of the Central Server Of Control software via FTP.

0 - Active mode.

1- Passive mode.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

PeriodRequestOfStatistic> 051.0 and later

The key sets the statistics polling period in minutes for the Servers Of Control.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

LogArchPeriod> 01681.0 and later

The key sets the log archiving period in hours of the Communication module (CentralNetServer.log)

x32: (x32-Monitoring)

x64: (x64-Monitoring)

LogMaxSize> 01001.0 and later

The key sets the maximum size of the communication module log file at which it begins to archive ignoring the LogArchPeriod parameter.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

LogArchDelPeriod> 031.0 and later

The key sets the log files archive retention period in months (CentralNetServer.log).

x32: (x32-Monitoring)

x64: (x64-Monitoring)

KeepDB> 061.0 and later

The key sets the data retention period of closed errors and alarms in the ServerSSTV DB.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

LastLoadThreshold >= 0301.0 and later

The key sets the time in minutes, after which, if the data in the MonitorSSTV database is outdated, the corresponding indication on the Server Of Control/CSC will appear.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

DisableMonitoring0, 101.0 and later

The key disables the ability to accept alarms and force error closing.

0 - the ability to confirm alarms and force error closing is enabled.

1 - the ability to confirm alarms and force error closing is disabled.

If the key is set to 1, then:

  • the area for comments and buttons for confirming the alarm are not displayed in the Reaction to alarm window; when you set the Confirm checkbox, nothing happens;
  • when you click on the Force error closing button on the toolbar, the window with confirmation of force error closing does not open.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

StreamViewerLowestPriority0, 101.0 and later

The key sets low priority of the StreamViewer process when it starts.

0 − The StreamViewer process starts with normal (medium) priority.

1 − The StreamViewer process starts with low priority.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

SleepAfterDisarminteger in msec501.0 and laterThe key sets the time interval of recording delay in msec after disarming the camera

x32: (x32-Monitoring)

x64: (x64-Monitoring)

SleepAfterRecStopinteger in msec501.0 and later

If the continuous recording mode is enabled, the key sets the time interval of recording delay by camera in msec after it stops.

If the camera is armed, the key sets the time interval of camera arming delay in msec after it stops

x32: (x32-Monitoring)

x64: (x64-Monitoring)

KeepVideoDataInBase> 001.0 and later

If the parameter isn’t created or equals 0, the video data isn’t stored in the Monitoring database (MonitorSSTV or ServerSSTV).

If the parameter > 0, its value equals the number of days the video data should be stored in the Monitoring database. When this period is exceeded, the video data is deleted from the database

x32: (x32-Monitoring)

x64: (x64-Monitoring)

 

GroupingCameras1-20002.0 and later

If you don't create the parameter or it equals 0, cameras aren't divided into groups

If the parameter > 0, its value equals the number of cameras in the group

x32: (x32-Monitoring)

x64: (x64-Monitoring)

 

CarPlatesBlackList0, 102.0 and later

If you don't create the parameter or it equals 0, the transmission of the LPs' blacklist is disabled.

If the parameter value is 1, the transmission of the LPs' blacklist is enabled

x32: (x32-Monitoring)

x64: (x64-Monitoring)

ClearVideoDataPeriod>002.0 and later

The key determines the number of hours after which the video information that appears in the Video data window can be deleted.

The key is installed on the computer with the Server of Control module.

If the parameter equals 0, the video data is deleted as usual after 30 days.

If the parameter >0, the irrelevant data is deleted after this number of hours

x32: (x32-Monitoring)

x64: (x64-Monitoring)

HideIpCam0, 102.0 and later

The key hides the camera IP address in the Reaction to alarm window when you press the Camera button on the control panel:

0—the camera IP address is displayed

1—the camera IP address is hidden

Restricting the Operator’s access to the camera's functional menu and its options

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

MENU_DISABLE_OPTION0, 101.0 and later

The key hides the camera's menu.

0 - The menu is displayed.

1 - The menu is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

MENU_ARM_DISABLE_OPTION0, 101.0 and later

The key hides the Arm menu option.

0 - The Arm menu option is displayed.

1 - The Arm menu option is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

MENU_REC_DISABLE_OPTION0, 101.0 and later

The key hides the Start recording menu option.

0 - The Start recording menu option is displayed.

1 - The Start recording menu option is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

MENU_CAMS_DISABLE_OPTION0, 101.0 and later

The key hides the Camera menu option.

0 - The Camera menu option is displayed.

1 - The Camera menu option is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

MENU_TITLES_DISABLE_OPTION0, 101.0 and later

The key hides the Show titles menu option.

0 - The Show titles menu option is displayed.

1 - The Show titles menu option is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

MENU_PROCESSING_DISABLE_OPTION0, 101.0 and later

The key hides the Processing menu option.

0 - The Processing menu option is displayed.

1 - The Processing menu option is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

MENU_EXPORT_DISABLE_OPTION0, 101.0 and later

The key hides the Export menu option.

0 - The Export menu option is displayed.

1 - The Export menu option is hidden.

Restricting the Operator’s access to the Processing menu within the camera's functional menu

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

MENU_PROCESSING_DEINTERLACE_DISABLE_OPTION0, 101.0 and later

The key hides the Deinterlacing menu option.

0 - The Deinterlacing menu option is displayed.

1 - The Deinterlacing menu option is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

MENU_PROCESSING_ZOOM_DISABLE_OPTION0, 101.0 and later

The key hides the Zoom-in menu option.

0 - The Zoom-in menu option is displayed.

1 - The Zoom-in menu option is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

MENU_PROCESSING_CONTRAST_DISABLE_OPTION0, 101.0 and later

The key hides the Contrast menu option.

0 - The Contrast menu option is displayed.

1 - The Contrast menu option is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

MENU_PROCESSING_MASK_DISABLE_OPTION0, 101.0 and later

The key hides the Detector mask menu option.

0 - The Detector mask menu option is displayed.

1 - The Detector mask menu option is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

MENU_PROCESSING_SHARPNESS_DISABLE_OPTION0, 101.0 and later

The key hides the Sharpen menu option.

0 - The Sharpen menu option is displayed.

1 - The Sharpen menu option is hidden.

Restricting the Operator’s access to the CamMonitor component buttons

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

BUTTON_ARCH_DISABLE_OPTION0, 101.0 and later

The key hides the Archive button.

0 - The Archive button is displayed.

1 - The Archive button is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

BUTTON_TIME_DISABLE_OPTION0, 101.0 and later

The key hides the time.

0 - The time is displayed.

1 - The time is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

BUTTON_NAME_DISABLE_OPTION0, 101.0 and later

The key hides the camera name.

0 - The camera name is displayed.

1 - The camera name is hidden.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

BUTTON_MENU_DISABLE_OPTION0, 101.0 and later

The key hides the Menu button.

0 - The Menu button is displayed.

1 - The Menu button is hidden.

Restricting the Operator’s access to the CamMonitor control via the keyboard and mouse

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

KEYS_DISABLE_OPTION0, 101.0 and later

The key disables the control over the CamMonitor component using the hotkeys available for Video Monitor (see Video surveillance monitor).

0 - The control over the CamMonitor component using the hotkeys is enabled.

1 - The control over the CamMonitor component using the hotkeys is disabled.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

TELEMETRY_ENABLE_OPTION0, 101.0 and later

The key enables the Telemetry control using the CamMonitor component (see Telemetry control).  

0 - The Telemetry control using the CamMonitor component is disabled

1 - The Telemetry control using the CamMonitor component is enabled.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

ARCH_DELETE_ENABLE_OPTION0, 101.0 and later

The key activates the Delete menu item which is used to remove the recordings from the archive (see Deleting video recordings from the archive).

0 - The Delete item is hidden.

1 - The Delete item is displayed.

x32: HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\CamMonitor

x64:HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\CamMonitor

ARCH_PROTECT_ENABLE_OPTION0, 101.0 and later

The key activates the Protect menu item which is used to protect the archive recordings from rewriting (see Protection of separate record and disable of protection).

0 - The Protect item is hidden.

1 - The Protect item is displayed.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

RequestFullStatisticOnStartup 
0, 101.0 and later

By default, the Central Server Of Control requests a complete package of statistics from all Servers Of Control only once, when it first connects to the Servers Of Control.

The key activates the request on the Central Server Of Control for a complete statistics package from all Servers Of Control every time the CentralNetServer.exe communication module is launched.

0 - disabled.

1 - a complete statistics package will be requested from all Servers Of Control each time the CentralNetServer.exe communication module is launched.

Attention! Requesting a complete statistics package is a resource-intensive operation. It is only necessary to activate this key if absolutely necessary.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

RequestFullStatistic[N]

Note. [N] is the internal identifier of the Server Of Control object in Axxon PSIM

0, 101.0 and later

By default, the Central Server Of Control requests a complete package of statistics from all Servers Of Control only once, when it first connects to the Servers Of Control.

The key activates the request for a complete statistics package from a specific Server Of Control once. The request will be executed when the CentralNetServer.exe communication module is launched, and the value of this key will automatically change to 0.

0 - disabled.

1 - a complete statistics package from a specific Server Of Control will be requested once when the CentralNetServer.exe communication module is launched.

Attention! Requesting a complete statistics package is a resource-intensive operation. It is only necessary to activate this key if absolutely necessary.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

FtpPathText<Axxon PSIM installation directory>\Vhost\DATA\FTP\1.0 and later

Sets the path to the FTP directory on the Server Of Control for working with the Central Server Of Control.

x32: (x32-Monitoring)

x64: (x64-Monitoring)

ExportPathText

DISK:\Export\

, where DISK is the drive on which the operating system is installed

NASets the path to the export directory on the Server Of Control

...