...
What's new in
...
Axxon PSIM build 1.0.1.
...
1378
Performed a number of modifications that increased the system operation stability.
New features in Axxon PSIM 1.0.1
...
- Now you can change the statistics update rate on the settings panel of the State statistics object.
- Now the SQLEXPRESS2019 database is used instead of the SQLEXPRESS2014 one for the Axxon PSIM operation.
- Now the value of the Ring parameter in the Video subsystem section of the Advanced tweaki.exe setup utility is 15000 MB by default, upon reaching which, the process of removing old recordings for the loop recording starts
Image Removed - Now on the settings panel of the VideoGuard integration client object, you can select only your own IP address for each IP interface.
- Removed the Report.exe utility.
- Added the new registry key
Image Removed- HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\AxxonSoft\Axxon PSIM\Video that, by using the GuiLayoutMode=1 parameter, can disable the part of the operator protocol interface.
Added new registry keys
Image Modified- HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\AxxonSoft\Axxon PSIM that, by using the ChromiumWebBrowserDevToolsEnable=1 parameter, enables using the F12 hotkey to open DevTools in the Axxon One archive browser that is called from Axxon PSIM when you work with the NGP manager module.
- HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\AxxonSoft\Axxon PSIM\Inc_Server that, by using
the - the LogDbQueryDuration=1 parameter, enables in the database the logging of the request execution duration of the Incident server module.
- Added the INC_SERVER|1|UPDATE_PRIORITY reaction to change the events' priority of the Incident server module using the script in the JScript language

- In HTTP API:
- Now when you use the GET http://IP address:port/web2/secure/persons?id={id} request, you can receive the user information that contains its encoded image if present

- Added the new GET http://IP address:port/web2/secure/persons/acrs request to receive the list of virtual access points.
- Added the new ext_id_person parameter to the body of the POSThttp://IPaddress:port/web2/secure/persons/checkByServer request that you can use only if the id_person parameter is absent.
- Now in the operator protocol window on the Search in events archive tab, you can reopen an event by calling the context menu. After that, this event is moved to the current events tab and stays available for the archive search until reprocessing. Also, when you open the ActiveX window on an alarm event, the ActiveX windows are opened on all cameras linked with this object.
Added the list of objects that are currently in certain states on the Chart tab of the State statistics window
Image Modified
- Now when you use the ARCH_BOOKMARK_RECORD command script in the JScript language, you can add a bookmark. Using the RECORD ARCH_UNBOOKMARK_PERIOD command, you can remove all bookmarks that are completely included in the specified period.
- Now when you work with Axxon One using the NGP manager module, after you start a macro in Axxon PSIM, the corresponding macro starts in Axxon One

- Now if you preinstall at least one Axxon One client in the settings of the NGP manager object, then when you create the integration object in the Path field, the path to the Axxon One root folder is automatically specified. Otherwise, you must install it and after that, enter manually either the path to the Axxon One root folder or the gui_safe_mode.exe path if the OpenGL version is outdated

- Now the wrong frame is displayed blurred in the operator protocol window as long as the proper one doesn't come.
- Now in the operator protocol window on the Current events tab, action buttons are active only if an event is selected. If you click on any other place, they become inactive

- The monitor icon is now displayed on the taskbar.
...
The release includes the Drivers Pack 3.82.343 for IP device support. Detailed information about the Drivers Pack, where to find the latest set of drivers, and the list of supported hardware is available at https://www.axxonsoft.com/integrated_security_solutions/supported-ip/.
Updating from previous version
To update from version 1.0.1 and earlier, run the new version's installer and perform the installation with the configuration saved. No need to uninstall the previous version.
Product documentation
Requirements for the base computer
...