Files from the <Axxon PSIM software installation>/Vhost/UPS/Ext directory will look for the ini settings INI-file in the same directory as the StateUPS utility.

...

  1. Address – address of the machine on which Agent of Control is running. The default value of this parameter is 127.0.0.1. If you install StateUPS on the same computer on which Agent of Control is installed, it is not necessary to change this parameter.
  2. Port – TCP port to which StateUPS sends messages from the UPS. The value of this parameter must match the corresponding setting of Agent of Control, TCP port (UPS) (see the section Configuring a port for incoming UPS messages).

...

  1. Create HKLM\SOFTWARE\BitSoft\VHOST\VHostService section in the registry for 32-bit OS (HKLM\SOFTWARE\Wow6432Node\BitSoft\VHOST\VHostService for 64-bit) on this computer.
  2. In this section, create the FolderLog parameter. In the FolderLog parameter specify the path where the UPS folder will be created containing INI-file. For example, if the folder is C:\EVUPS, then FolderLog = C:\EVUPS\.
  3. In the specified folder, for example, C:\EVUPS, create the UPS sub-folder and copy the StateUPS.ini into it.