Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • Fast traffic (highways, 80 km/h or more):
    Expand
    titleExample of parameter settings
    ParameterValue
    Initiate event in (sec)0
    Minimum number of same LP readings1
    Maximum number of same LP readings5
    Recognition timeout (sec)12
    Frame processing period (sec)0
  • Standard city traffic:
    Expand
    titleExample of parameter settings
    ParameterValue
    Initiate event in (sec)0
    Minimum number of same LP readings2
    Maximum number of same LP readings10
    Recognition timeout (sec)35
    Frame processing period (sec)60
  • Checkpoints, barriers (slow traffic):
    Expand
    titleExample of parameter settings
    ParameterValue
    Initiate event in (sec)12
    Minimum number of same LP readings23
    Maximum number of same LP readings1520
    Recognition timeout (sec)5 or greater
    Frame processing period (sec)120
    Period of ignoring repeated recognitions (sec)60-300
  • Parking lot:
    Expand
    titleExample of parameter settings
    ParameterЗначениеValue
    Initiate event in (sec)0
    Minimum number of same LP readings2
    Maximum number of same LP readings10
    Recognition timeout (sec)35
    Frame processing period (sec)300 or greater
  • Difficult conditions (dirt, damage, poor lighting):
    Expand
    titleExample of parameter settings
    ПараметрParameterЗначениеValue
    Extra processing for LP searchYes
    Minimum character confidence threshold5070
    Minimum authenticity threshold5070