Go to documentation repository
Page History
...
- Fast traffic (highways, 80 km/h or more):
Expand title Example of parameter settings Parameter Value Initiate event in (sec) 0 Minimum number of same LP readings 1 Maximum number of same LP readings 5 Recognition timeout (sec) 1–2 Frame processing period (sec) 0 - Standard city traffic:
Expand title Example of parameter settings Parameter Value Initiate event in (sec) 0 Minimum number of same LP readings 2 Maximum number of same LP readings 10 Recognition timeout (sec) 3–5 Frame processing period (sec) 60 - Checkpoints, barriers (slow traffic):
Expand title Example of parameter settings Parameter Value Initiate event in (sec) 1–2 Minimum number of same LP readings 2–3 Maximum number of same LP readings 15–20 Recognition timeout (sec) 5 or greater Frame processing period (sec) 120 Period of ignoring repeated recognitions (sec) 60-300 - Parking lot:
Expand title Example of parameter settings Parameter ЗначениеValue Initiate event in (sec) 0 Minimum number of same LP readings 2 Maximum number of same LP readings 10 Recognition timeout (sec) 3–5 Frame processing period (sec) 300 or greater - Difficult conditions (dirt, damage, poor lighting):
Expand title Example of parameter settings ПараметрParameter ЗначениеValue Extra processing for LP search Yes Minimum character confidence threshold 50–70 Minimum authenticity threshold 50–70