The appearance of the settings panel of the Computer system object is shown in the figures. The description of the settings of the Computer system object is given in the table.

TheArchive disksand Basic settings tabs

...

Recording
column

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the computer name in the local network

Digits, letters, periods, hyphen, dash, underscore, and any characters

NA

Depends on the number of the Computer objects registered in the system.

Number of characters—from 1 to 15

2

The Name*
field

Enter the value in the field

Sets the name of the Computer object in the video surveillance system with distributed architecture

Latin alphabet, Cyrillic, digits and service characters

Computer

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the Computer object in the video surveillance system with distributed architecture 

Boolean type

Clear

Set—the Computer object is disabled and isn't used

Clear—the Computer object is enabled and used

The Archive disks tab

4

The Video
checkbox

Set the checkbox

Sets the disk for storing the video archive from cameras and also audio archive during synchronous audio and video recording


Boolean type

Clear

Set—the disk is used for storing the video archive

Clear—the disk isn't used for storing the video archive


5

The Audio
checkbox

Set the checkbox

Sets the disk for storing the audio archive from microphones

Boolean type

Clear

Set—the disk is used for storing the audio archive from microphones

Clear—the disk isn't used for storing the audio archive from microphones


6

The Disk
column

Automatically, enter the value in the field

Displays the names of the local disks available for storing the video and audio archives and also used to enter the names of the network disks used for archive storage.

Note. When writing an archive to a specific disk, the disk name and characteristics are highlighted in bold, and the information on free space is updated dynamically

Names of the local disks (Latin alphabet), names of the network disks (UNC paths)

NA

Depends on the total number of the local and network disks

7

The GB column

Automatically

Displays the amount of free space on each available disk

Note. When writing an archive to a specific disk, the disk name and characteristics are highlighted in bold, and the information on free space is updated dynamically

Disk space in GB

NA

Depends on the total free disk space

8

The

Automatically

Displays the current disk for the archive recording

Boolean typeNA

Set—the archive is currently recorded on the specified disk

Clear—the archive isn't currently recorded on the specified disk

The Basic settings tab

98

The Connection
field

Enter the value in the field

Sets the name of the modem connection used in Windows

Latin alphabet, Cyrillic, digits and service characters

NA

A line containing a sequence of any characters (letters, digits, service characters).

Number of characters from 1 to 30

109

The Username
field

Enter the value in the field

Sets the login of the modem connection used in Windows

Latin alphabet, Cyrillic, digits and service characters

NA

A line containing a sequence of any characters (letters, digits, service characters), case-sensitive.

Number of characters from 1 to 30

1110

The Password
field

Enter the value in the field

Sets the password of the modem connection used in Windows

Latin alphabet, Cyrillic, digits and service characters

NA

A line containing a sequence of any characters (letters, digits, service characters), case-sensitive.

Number of characters from 1 to 30

1211

The Disable logging
checkbox

Set the checkbox

Disables the event logging to the event viewer database on the local computer

Boolean type

Clear

Set—events aren't logged into the event viewer database

Clear—events are logged into the event viewer database

1312

The Only local protocols
checkbox

Set the checkbox

Enables logging to the events viewer database only the information about the events registered on this computer

Boolean type

Clear

Setonly the events registered on this computer are logged into the event viewer database

Clear—all required events are logged into the event viewer database

1413

The Parameters logging checkbox

Set the checkbox

Enables the event parameters logging

Boolean type

Clear

Set—event parameters are logged

Clear—event parameters aren't logged

1514

The Time synchronization
checkbox

Set the checkbox

Sets the time synchronization of all computers in the distributed system with the system time of this computer.
Time is automatically synchronized at midnight every 24 hours or when Axxon PSIM is started on the server that is the source of the time synchronization

Boolean type

Clear

Set—time is synchronized

Clear—time isn't synchronized


1615

The Events archive length____days
field

Enter the value in the field

Sets simultaneously the event storage period for:

  • events registered in the system on the local computer (Protocol table in the PSIM database or in a separate database);
  • Incident server events (PROTOCOL_INC_SERVER table in the PSIM database)

Days

NA

More than 1

17

The Run x64 modules
checkbox

Set the checkbox

Sets the way to run the 64-bits modules

Boolean type

Up to 4.10.2Clear, starting from 4.10.3Set

Set—when you attempt to run a module, the 64-bit module variant runs. If such variant isn't found, the 32-bits module runs

Clear—64-bits modules don't run

16The 18The Use as client checkboxSet the checkboxIndicates that the computer is a client in the distributed video surveillance systemBoolean typeClear

Set—computer is used as a client

Clear—computer is used as a server or a RAW

1917The Prevent Sleep mode checkboxSet the checkboxDisables the Windows OS sleep modeBoolean typeSet

Set—computer doesn’t switch to the sleep mode

Clear—computer switches to the sleep mode 20

18

The Initial display
drop-down list

Select a value from the list

Sets the default display to be displayed after starting Axxon PSIM. If you don't select the display, the last active display is displayed after Axxon PSIM starts

Names of the Display objects registered in the system

NA

Depends on the number of the Display objects registered in the system

2119

The Default user drop-down list

Select a value from the list

Sets the default user, that is, the user with the rights to start Axxon PSIM without a password

Names of the users registered in the system

NA

The list of users registered in Axxon PSIM

22

The Ip WizardCamera discovery tool
button

Click the button

Access to create, configure, and edit IP devices

NA

NA

The Camera discovery tool window that opens displays all available settings.

For more details, see Camera discovery tool

...

The Protocol synchronization tab

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Synchronize
checkbox

Set the checkbox

Activates the synchronization of the event viewer databases between the local and remote computers



Boolean type

Clear

Set—event viewer databases of the local and remote computers are synchronized

Clear—event viewer databases of the local and remote computers aren't synchronized

2

The Computer
field

Automatically

Displays the network name of the remote computer with which you must synchronize the event viewer database

Latin alphabet and service characters

NA

Depends on the number of the Computer objects registered in the system

3

The Name
field

Automatically

Displays the name of the remote computer in the network

Latin alphabet, Cyrillic, digits and service characters

NA

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of charactersfrom 1 to 60

4

The Change Connection String
button

Click the button

Enables the options of configuring and editing the connection parameters to the remote computer event viewer database

NA

NA

NA

The Archive synchronization tab

...