A cross line detector detection tool is a VMDA detector detection tool that triggers when the object trajectory of an object that is in the camera coverage and FOV crosses a virtual line.

To configure a cross line detector, do the following:

  1. Go to the the VMDA detection object settings panel for a VMDA detection object.
  2. Select a line type (straight or polyline) the crossing of which leads to a detector triggering. Only one line can be added. The first line will be deleted if there is an attempt to add a second one.    
    1. If a detector is to trigger while crossing a straight line, click the the Add line button  button (1).
    2. If a detector is to trigger while crossing a polyline, click the the Add polyline button  button (2).
  3. In the the Video preview field  field (4), set the end point points of the line, by clicking left mouse button, which crossing leads to a detector triggering.
    Image ModifiedImage Modified
  4. Make the necessary operations with a line. Line The operations are shown in the table.

    Operation

    Result

    Left mouse click in the video surveillance window

    Creation of a line’s end point

    Hover to an end point and holding the left button pressed move the mouse

    Shift of a line’s end point

    Hover to an end point and click the right mouse button

    A line’s deletion


  5. To select object type for which the detector will be enabled, click the Image Removedthe Image Added symbol. Available object types are:

    1. Image Removed Any Image Added Any object. Detector  Detector triggers when the line is crossed by any objectImage Removed Man. Detector
    2. Image Added A human. Detector triggers when the line is crossed by a manImage Removed Vehicle. Detector an object which width is less than height.
    3. Image Added Vehicle. Detector triggers when the line is crossed

      by a vehicle

      by an object which width is greater than height.

      Info
      titleNote.

      Detection of the following object types can be configured using scripts and registry keys: a human, a group of humans (with a possibility to count the number of people in a group), a vehicle, noise, an object carried into the area, an object carried out of the area, other objects. See also CAM_VMDA_DETECTOR VMDA detection section of the Guide for creating scripts (programming).

      More precise objects classification can be performed using the neural filter (see Configuring the neural filter).


  6. To set the object color to be triggered by the detector, click the Image Added icon. The color picker palette will open. Circle the required color range with the left mouse button.
    Image Added

    To reset the selected color range to the default value, right-click in the palette area.

  7. By default, the detection tool triggers on line crossing in both directions. Click

    By clicking

    the left mouse button upon one of the

    grey arrows, set the object’s direction across the line by which the detector will trigger

    arrows to ignore crossing in one of the directions. The arrow will be colored

    white.Approximate speed of detected objects when the detector triggers is displayed close to arrow. At minimal and maximal

    gray.

    Info
    titleNote

    When just added, the arrow has minimum length.


    The approximate speed of detected objects as a percentage of the frame per second is displayed near the arrow. Change the speed by moving the arrow head with pressed left mouse button and changing the arrow length. The detection tool is triggered when an object crosses the line in the selected direction with a speed that is approximately the same as the specified speed. At minimum and maximum value of speed the "?" sign will display and the fact of

    cross

    line crossing will be detected regardless of

    speed will be detected. It is possible to change value of speed by changing arrow length moving arrowhead with pressed left mouse button

    the speed.
    In order for the detection tool to be triggered when object speed is less than the specified speed, specify the id of the detection tool in the VMDA.useSpeedLimitTypeLessThan parameter (for details on the key, see Registry keys reference guide).
    In order for the detection tool to be triggered when object speed is greater than the specified speed, specify the id of the detection tool in the VMDA.useSpeedLimitTypeMoreThan parameter (for details on the key, see Registry keys reference guide).

    Info
    titleNote.
    Arrow has minimal length while adding.
    Image Removed

    For more information about working with the registry, see Working with Windows OS registry.


    Note
    titleImportant!

    The same VMDA detector id can only be specified for either the VMDA.useSpeedLimitTypeLessThan or the VMDA.useSpeedLimitTypeMoreThan parameters. The simultaneous operation of both these parameters for the same VMDA detector is not allowed.


    Image Added

    Info
    titleNote.
     It

    It is necessary to set at least one

    object’s

    object direction across the line.


    Info
    titleNote.
     If

    If both directions are set, the detector will trigger at

    any

    line crossing by an object in any direction.


  8. If the alarm is to

    Set the Generate alarm on camera checkbox (5), if the camera alarm should be generated when the detector triggers.

  9. To display the tracks of objects detected by the cross line detection tool regardless of whether the corresponding setting of the Tracker object is enabled, set the Generate alarm on camera checkbox (5) Show event on screen checkbox (6).
  10. If the video in the preview window is too distorted, set the Show actual video aspect ratio checkbox (7). In this case, the video may not occupy the entire area of the preview window.
  11. To save the changes, click

    the Apply

    the Apply button (

    6

    8).

    Info
    titleNote

...

...

  1. To clear the preview field from a visual

...

  1. element (a line), click

...

  1. the Clear button (3).


A cross line detector is now configured.