Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The Macro object is designed used to support the automatic execution of a pre-defined predefined sequence of commands upon the occurrence of certain events , registered by the Intellect™ systemregistered by Axxon PSIM. The settings panel of the Macro object is shown in the figure.

Image Modified

The table describes the setting parameters of the settings corresponding to the elements of the settings panel of the Macro object.

Parameter

Method for

entering

setting the parameter value

Parameter description

Symbols used

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Macro

command

 object in the video surveillance system

.

Sequence of numbers

Digits, letters, periods, hyphen, dash, and underscore

NA

A line containing numbers, letters, periods, hyphen, dash, and underscore

-

Depends on the number of the Macro

command

 objects in the

digital distributed

video surveillance system

.

with distributed architecture

2

The Name*
field

Enter the value

in the

in the field

Defines

Sets the name of the

Macro command object name.

 Macro object 

Latin alphabet, Cyrillic, digits, and service characters

Macro

A line containing a sequence of any

symbols

characters (letters, digits, service characters

apart from

except > and <

symbols

characters), case-insensitive.

Number of

symbols – from

characters—from 1 to 60

.

3

The Disable
checkbox

Is identified by the check mark

Defines the Macro command object status (enabled or disabled).

Set the checkbox

Disables the Macro object 

Boolean type

Not available

Yes – the Macro command

Clear

Setthe Macro object is disabled and

is not in use

isn't used

Clearthe Macro 

No – the macro command

object is enabled and

is in use.

used

The Settings

Group

 group

4

The State
drop-down list

Enter the value in the field

Defines

Sets the message displayed in the information board of the main menu of

the Intellect system,

 Axxon PSIM when the given macro

command

is running

.

Latin alphabet, Cyrillic, digits, and service characters

Not defined

NA

1.

Standard

no message

will be

is displayed in the information board of the main menu of

the Intellect system

 Axxon PSIM.

2.

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols –

charactersfrom 1 to 60

.

5

The Local
checkbox

Is identified by the check mark

Set the checkbox

Sets

Defines

the computers, which will execute the given macro

command

(on all computers of the

digital distributed

video surveillance system with distributed architecture or only on the given computer).

Note. This checkbox

does not apply to Hide and Show

doesn't apply for hiding and showing reactions of any Display. Regardless of the checkbox,

wen called

when calling from the Server/RAW,

they

the reactions are executed on the Server/RAW and all connected Clients; when

called

calling on the Client,

they

the reactions are executed only on the

client.

Client

Boolean type

Not available

Clear

Setthe macro is executed only on the given computer

Clear

Yes

the given macro

command will be

is executed

by

on all computers of the

digital distributed

video surveillance system

.

No – the macro command will be executed only by the given computer.

6

Hidden

Is identified by the check mark

Defines, whether or not this macro command will be

with distributed architecture

6

The Hidden
checkbox

Set the checkbox

Determines whether the name of this macro is displayed in the main control panel of

the Intellect system

 Axxon PSIM to be

launched

started manually

.

Boolean type

Not available

Clear

Set—the name of the macro isn't

Yes – no macro command will be

displayed in the main control panel

of the Intellect system.

of Axxon PSIM

Clearthe name of the macro is

No – the macro command will be

displayed in the main control panel of

the Intellect system.

 Axxon PSIM

The Events subgroup

Events Subgroup

7

The Type

Is selected

drop-down list

Select the value from the list

Defines

Sets the type of objects in the

digital distributed

video surveillance system with distributed architecture, in which

registration of events initiates macro command execution.

the event registration triggers a macro

Types of objects registered in the system

.

Empty field
NA

Depends on the total number of the types of objects created in the

digital distributed

video surveillance system

.

with distributed architecture

8

The Number


drop-down list

Select the value

Is selected

from the list

Defines

Sets the identification number of the object in the

digital distributed

video surveillance system with distributed architecture, in which

registration of events initiates macro command execution.

the event registration triggers a macro

Sequence of numbers

Empty field
NA

Depends on the total number of the

given types of objects

objects of the specified type created in the

digital distributed

video surveillance system

.

with distributed architecture

9

The Name
field

Automatically

Displays the name of the selected object in the

digital distributed

video surveillance system

.

with distributed architecture

Name

Names of

the 

the objects of the

same

specified type registered in the system

Empty field
NA

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols –

charactersfrom 1 to 60

.

10

The Event


drop-down list

Select the value

Is selected

from the list

Defines

Sets the event

, which, when registered

that triggers a macro for the

pre-defined object, initiated macro command execution.

specified object

Names of the events available

Events registered

for the given type of objects

.

Empty field
NA
List

A list of events is created

separately

individually for each type of object

.

The Parameters

Subgroup

 subgroup

NOTE

Note. The given subgroup

is not

isn't active for

some

all types of objects

.

11

The Name
field

Automatically

Defines an additional

Sets the name of the additional parameter for the selected type of object in the Events subgroup

.

Latin alphabet, Cyrillic, digits, and service characters

and digits.

Not defined
NA

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols – from

characters—from 1 to 60

.

12

The Value
field

Enter the value in the field

Defines

Sets the value for the parameter

of

in the Name column

.

Latin alphabet, digits, and service characters

and digits.

Empty field
NA

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols –

charactersfrom 1 to 250

.

The Action

Subgroup

 subgroup

13

The Type


drop-down list

Select the value

Is selected

from the list

Defines

Sets the type of objects in the

digital distributed

video surveillance system

,

with distributed architecture to which the command is forwarded

,

when the conditions

defined

set in the Events subgroup

for

to trigger a macro

command initiation

are met

.

Types

Names of the types of objects registered in the system

.

Empty field

NA

Depends on the total number of the types of objects created in the

digital distributed

video surveillance system

.

with distributed architecture

14

The Number

Is selected

drop-down list

Select the value from the list

Defines

Sets the identification number of the object in the

digital distributed

video surveillance system

,

with distributed architecture to which the command is forwarded

,

when the conditions

defined

set in

the

the Events subgroup

for

to trigger a macro

command initiation

are met

.

Sequence of numbers

Empty field

Depends on the total number of the

given types of objects created

objects of the specified type in the

digital distributed

video surveillance system with distributed architecture.

If the field is left blank, the reaction

will be

is performed for all objects of the selected type.

If you enter the # symbol

#

in the field, the identifier of the object from which the event was received

will be

is substituted into the reaction.

Object

The object types in the Events and Actions tables may differ. When the macro is run manually from the main control panel, the # symbol is treated as if the field

was

is blank

, i.e.

, that is, the macro is executed for all objects of the selected type.
Example of using the # symbol: disarm the camera if the

“Detach”

 Detach event is received from it

.

15

The Name
field

Automatically

Displays the name of the selected object in the

digital distributed

video surveillance system

.

with distributed architecture

Name

Names of

the 

the objects of the

same

selected type registered in the system

Empty field
NA

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols –

charactersfrom 1 to 60

.

16

The Action

Is selected

drop-down list

Select the value from the list

Defines

Sets the action

, which

that the given device performs

,

when the conditions

for

to trigger the given macro

command initiation

are

met.

met 

Names of the actions available in

Actions, registered by

the system for the

given type of objects.

Empty field

objects of the specified type

NA

A list

List

of events is created

separately

individually for each type of object

.

The Parameters

Subgroup

 subgroup

NOTE

Note. The given subgroup

is not

isn't active for all types of objects

.

17

The Name
field

Automatically

Defines an

Sets the name of the additional parameter for the selected type of object in the Actions subgroup

.

Latin alphabet, digits, and service characters

and digits.

Not defined
NA

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols – from

characters—from 1 to 60

.

18

The Value
field

Enter the value in the field

Defines

Sets the value for the parameter

of

in the Name column

.

Latin alphabet, digits, and service characters

and digits.

Empty field
NA

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols –

charactersfrom 1 to 250

.

Outside
Out of the
groups
group




19

The Response sending delay (

sec.

s)
field

Enter the value in the field

Sets the time period

(

in seconds

)

that must pass after the events specified in the Events column occur and before executing the reactions specified in the Actions column.


Note. If the events reoccur before the specified time period expires, the reaction execution

wait

 waiting period is prolonged

, i.e. reactions will be

, that is, reactions are executed only once when events

do not

don't reoccur over the specified period

.

Integer number

Sequence of numbers

NA
-

>0

20The Fast call
field

Left-click in the field and

click

press the required key combination

Sets a keyboard shortcut for a macro.

Note.

 

If the same combination of

hot

keys is set for several macros, then when

clicking

pressing a key combination, all of these macros will run

.

Key combinations
No
Clear
Some
Individual keys of the main or numeric keyboard, as well as
these
the given keys in combination with Shift, Ctrl, and Alt
.
21The Icon type
dropdown

drop-down list
Select
in
the value from the
dropdown
list
.

Sets a set of icons for displaying a macro on the map. By default, an empty value is set

for

for all macros, which corresponds to the Macro 1 icon.

Note. Changing the icon

appearance

type will take effect after restarting the map interface. To restart the interface, restart

Intellect

Axxon PSIM or log in once again under the corresponding Operator account

.

Available icon

appearances

types on the map

-

Empty value
  • Empty value,
  • Macro 1
-
  • Macro 7
, empty value.

*The name Name of the element is not isn't displayed in the User’s rights settings panel of the given object.