The Program object creates is used to create specialized programs in the embedded programming environment of the INTELLECT™ software Axxon PSIM.
The settings panel of the Program object is shown in the figure.
The table Table describes the setting parameters of the settings corresponding to the elements of the settings panel of the Program object.
№
| Parameter | Method for |
setting the parameter value | Parameter description |
Representation | Default value | Value range | |
1 | The Identification number* field | Automatically | Displays the identification number of the Program object in the video surveillance system |
Sequence of numbers
Digits, letters, periods, hyphen, dash, and underscore | NA | A line containing digits, letters, periods, hyphen, dash, and underscores. |
Depends on the number of the Program objects in the |
video surveillance system |
with distributed architecture | ||
2 | The Name* field | Enter the value in the field |
Sets the name of the Program object |
Latin alphabet, Cyrillic, digits and service characters | Program | A line containing a sequence of any |
characters (letters, digits, service characters |
except > and < |
characters), case-insensitive. Number of |
characters—from 1 to 60 |
3 | The Disable checkbox |
Is identified by the check mark
Set the checkbox | Disables the Program object |
Boolean type |
Not available
Clear | Set—the Program |
object is disabled and |
isn't used Clear—the Program |
object is enabled and |
used |
4 |
Time zone
The Time schedule | Select the value |
from the list |
Sets the time period during which the given program |
operates | Name of the time schedule registered in |
the system | Never |
|
|
|
|
|
|
|
|
| ||||||
| The Computers group | ||||||
5 | The Select an element | |||||
Is identified by the check mark
checkbox | Set the checkbox | Sets the computer on which |
the given program |
is executed | Boolean type |
Not available
Clear | Set— |
the program |
is executed |
on the |
specified computer |
Clear—the program |
isn't executed on the specified computer | ||
6 | The Computer field | Automatically |
Sets the computer |
in the local network |
Computer |
names in the local network |
Computer name in the local network |
A line containing a sequence of any |
characters (letters, digits, service characters), case-insensitive. Number of |
characters—60 |
7 | The Name field | Automatically |
Sets the name of the computer |
Names of the Computer object registered in the system | Name of the Computer object registered in the system | A line containing a sequence of any |
characters (letters, digits, service characters), case-insensitive. Number of |
characters—60 |
| Out of the | ||||||
| group | ||||||
8 | ||||||
The Filter field | Enter the value in the field | Sets to pre-filter events processed by the program | Latin alphabet, Cyrillic, digits and service characters | NA | A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive. Number of characters—unlimited. The filter format is TYPE|ID|EVENT divided by semicolon. For example, the CAM||MD_STOP;CAM||MD_START format filters Alarm and Alarm end events from all Camera objects |
9 | The Text editor field | Enter the value in the field |
Enters the text of the executed program |
Latin alphabet, Cyrillic, |
digits and service characters | NA |
A line containing a sequence of any |
characters (Latin letters, digits, service characters), case-insensitive. |
Number of |
characters—unlimited |
* The name Name of the element is not displayed in the User’s rights isn't displayed on the settings panel of this object.