The parameters of the Windows setting panel are described in the table.
No | Parameter name | Field type | Description | Representation | Default value | Value range |
The Shell group | ||||||
1 | The Explorer/ | Set in the position | Selection of Windows working shell Attention! Disable UAC to run the | |||
Axxon PSIM software package as the shell. Configuration of the local security policy is required for full disabling of UAC in the Windows 8 and Windows 8.1 OS – see OS settings for correct operation of |
- | Explorer | Explorer – Microsoft Explorer is loaded as working Windows OS shell (corresponds to standard Windows OS settings). File – |
Axxon PSIM starts as a working shell of Windows OS |
2 | The File field with |
button. Active for the File switch position | Button is pressed | Opens standard Windows window «Open» to select shell file of OS Windows. Full path to the file is displayed in the field |
- | - | The |
psim.exe or |
psim_host.exe executive file is selected as a shell | ||||||
The Autologon group | ||||||
3 | The Enable checkbox | Checkbox | Activates automatic log on of the user to OS Windows | Boolean type | No | Yes – automatic log on of the user is activated |
No – automatic log on of the user is not activated |
4 | The Username field | Type-in the value | Set the username for logging on the OS Windows | - | - | Up to 64 characters. Depends on the settings of Windows user account (stored locally or on domain server) |
5 | The Password field | Type-in the value | Set the password for logging on the OS Windows | - | - | 8 to 14 characters Depends on the settings of Window’s user account (stored locally or on domain server) |
6 | The Domain field | Automatically | Displays the name of domain server (if there is any), where data concerning user account is stored (user name and password) | - | - | Depends on domain net settings (net settings of OS Windows correspondingly) |
7 | Restart |
Axxon PSIM on user login checkbox |
Setting checkbox | Specifies the way of restart the |
Axxon PSIM software installed as a service on user login |
Boolean type | Yes | Yes |
– the |
Axxon PSIM software installed as a service restarts under the current user if it belongs to the |
PSIM Users group |
No |
– The |
Axxon PSIM software installed as a service doesn't restart under the current user even for users belonging to the |
PSIM Users group |