Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The data about the events registered in the system is stored in the Protocol table in Axxon PSIM the Psim database (by default) or in the Protocol table of an individual database (see Extracting event protocol into an the Protocol table in a separate database (see Extracting event viewer into individual database).

The Event Viewer database is configured You can configure the database of the event viewer by means of the settings panel of the the Computer system object.Configure the Event Viewer database as follows:

  1. To disable
  2. events recording
  3. event logging to the
  4. Event Viewer
  5. database of the event viewer, set
  6. the 
  7. the Disable logging checkbox (1). This setting is relevant only for the
  8. Server
  9. server corresponding to
  10. the 
  11. the Computer object.
    Image Modified
  12. If you want to log to the Event Viewer database of the event viewer only the events registered on this computer, set the the Only local protocols checkbox (2). This  This setting is relevant only for the Server server corresponding to the the Computer object object.
    If you set this checkbox is set, then the Event Viewer database synchronization has to be started manually using the SyncProtocolyou must start the synchronization of the event viewer database manually, for example, using the Sync.exe utility or a macro (see see The SyncProtocolSync.exe console utility to synchronize event log database and Example of macro to start the Event Viewer databases synchronization).
  13. If you want to log all event parameters registered on this computer to the event viewer database, set the Parameters logging checkbox (3). This setting is relevant only for the server corresponding to the Computer object.
  14. In the the Events archive length field (4), specify the time period in days for storing the event archive in the Event Viewer database (3)event viewer database. This setting is relevant only for the Server server corresponding to the Computer the Computer object. To  To specify the time period for storing the event archive for all Servers in servers of the distributed system, use the common settings in the on the Programming tab (see The settings panel of the Security zone object). The value of the Events archive length parameter on the settings panel of the Computer object has the higher priority. If no value is specified you don't specify the value in the Events archive length field on the settings panel of the Computer object, the value specified in on the settings panel of the Security zone object is used.

    Info
    titleNote

    The specified Events events archive length is also applied to the events received by the Incident incident server , which that are stored in the PROTOCOL_INC_SERVER table of the Psim database.

    Info
    titleNote

    The process of clearing the database of the events older than the specified storage period is started by default every three minutes and deletes 100,000 events, starting with the oldest ones.

  15. Click the Apply button to save the changes (45).

The events Configuring event logging to the database is now configuredcomplete.

Info
titleNote
You can also use the tweaki.exe utility to configure events event logging (see the The Settings settings panel of the Axxon PSIM Base system section).
Tip

Define required Required disk space (size of event log viewer database)

Configuring the Operator protocol interface object

Configuring the Event Viewer interface object

Event control via Event Viewerevent viewer

Event processing using the Operator operator protocol

Configuring Incident incident server and Incident incident handler

Events control and processing Control and handling of events using the Incident incident manager