The You can create the Sensor system object is created under the Video Capture Device on the basis of the Video capture device object.

The Sensor object is created and main parameters are set in the following orderTo create and configure the main parameters of the Sensor object, do the following:

  1. Go to the Hardware tab in of the settings panel of  Axxon PSIM settings panel (1).
  2. Create the Sensor system object under on the basis of the Video Capture Devicecapture device object or select the corresponding object in the object tree in on the Hardwaretab on the settings panel of  tab of the Axxon PSIM settings panel (2).
  3. Specify When you create the Sensor object (3), you must specify the ID and , the name of the Sensor object and select the Video Capture Device object to become the parent of the Sensor object (3)capture device object based on which the Sensor object is created.

    Info
    titleNote

    If you use the Sensorsensor-Relay relay card is used, then specify that in the Sensor object settings, you must specify the video capture card with on the ADC to of which the Sensorthe sensor-Relay relay card is connectedinstalled.

  4. Select the channel number matching in accordance with the number of the output connector to which the sensor is connected physically (4).

  5. In the group of switches, select the alarm mode at which the sensor generates an event: at switch on or at switch off. By default, the alarm at switch on mode is selected (5).
    The executive device corresponding to the Sensor system object operates in one of two modes: alarm at switch on or alarm at switch off.
     

    Info
    titleNote

    Sensors connected to Panasonic IP-devices (of the i-Pro series ) trigger generate an event only at the switch off event.

    When For example, when you select the alarm at switch off mode is selectedfor the executive device of the Sensor type, the normal state of the sensor is openswitch on. When you switch it off, the sensor closesgenerates an event, it triggers and the corresponding actions set in Axxon PSIM are eventually performed in Axxon PSIM™.

  6. In the
  7. Hardware dropdown
  8. Detector drop-down list, select the type of executive device that is used as
  9. the detector in the guarded area
  10. a sensor on the protected facility (6).
    The
  11. Hardware
  12. Detector parameter is used for selecting the icon that is displayed on the interactive map. This parameter is
  13. essential
  14. required for the better perception of information
  15. (
  16. by the operator that is displayed on the
  17. map
  18. Map as object icons
  19. ) by Operator and for real-time intercepting by Operator if
  20. , as well as for the rapid operator reaction if such is required.
  21. Types of detectors available for the Sensor system object are given in the table.

    Hardware

    Description

    Infrared

  22. Icon
  23. The icon of the interactive map for the

  24. motion

  25. detectors
  26. detector

    PIR

  27. Icon
  28. The icon of the interactive map for the 

  29. device installed on the ceiling of the

  30. guarded area
  31. protected facility

    Glass

  32. Icon
  33. The icon of the interactive map for the 

  34. device installed on the window of the

  35. guarded area 
  36. protected facility andresponding when the window is broken

    Fire

  37. Icon
  38. The icon of the interactive map for

  39. the device
  40. the device responding to

  41. changes of heat conditions in the guarded area
  42. the heat condition changes at the protected facility

    Window

  43. Icon
  44. The icon of the interactive map for

  45. the 
  46. the device installed

  47. some distance away the window
  48. at a distance from a window and responding when the window is broken

    Smoke

  49. Icon
  50. The icon of the interactive map for

  51. the 
  52. the device responding to the smoke

  53. in the guarded area  
  54. appearance at the protected facility

    Reed switch

  55. Icon
  56. The icon of the interactive map for the 

  57. device

  58. responding
  59. that responds to locking/

  60. unlocking 
  61. unlocking a window, door,

  62. etc.
  63. and so on

  64. Click the Apply button to save the changes.

...

After you create the sensor in the objects tree, it

...

is in the "Armed" state. To change the

...

sensor state, use a macro (see the Creating and using macros section) or control the

...

sensor from the

...

map (see the Configuring the interactive map for object state indication and controlling the objects and Operations with sensors

...

sections). If you arm the

...

sensor,

...

the "Alarm" event appears when you switch on/switch off the

...

sensor depending on the alarm mode

...

setting—see step 5 above. If you disarm the

...

sensor, the "

...

Switch off"/"

...

Switch on" events appear correspondingly.

Info
titleNote.

Axxon PSIM requests the sensor state 3 three times per second. Short-term triggering event generations that last for less than 1/3 of a second can be skipped.

Creating and configuring the connection channel of the Sensor system object is completedcomplete.