Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Note
titleAttention!

Before you start working with the utility, check the value of the IndexRebuilding parameter in the section HKLM\SOFTWARE\AxxonSoft\PSIM\Video for

32

64-bit systems (HKLM\SOFTWARE\Wow6432Node\AxxonSoft\PSIM\Video for

64

32-bit)

section

of the Windows OS

Windows

registry: by default it

should

must be 0. If the parameter value differs from the default value

by default

, you

should

must change it to 0; otherwise,

otherwise

the utility

will not

won't index the archive.

Info
titleNote

We recommend starting the process of reindexing using the index.exe utility after shutting down Axxon PSIM.

To reindex the archive files after its changing you change it (for example, after copying new video recordings to one or several archive disks), do the following:

  1. Start the index.exe utility (see Starting and shutting down the index.exe utility section).
  2. In
  3. appeared window
  4. the window that opens, select archive disks for reindexing by setting
  5. checkbox
  6. the checkboxes next to the required disks (1).
  7. Check Select All to set all checkboxes

  8. Image Added
    Info
    titleNote

    The utility displays all available system disks, including the mountednetwork ones. The unmountednetworkdisks selected for video archive recording in Axxon PSIM aren't displayed.

  9. To select all disks for video archive reindexing, set the Select all checkbox (2).
  10. To start reindexing, click

  11. the
  12. the Start button (3).

  13. Image Removed
  14. The reindexing process is displayed in the field (4).

    Info
    titleNote
  15. .
  16. At the time of
  17. During reindexing, all

  18. the
  19. elements of the utility window are

  20. not active
  21. inactive.

  22. Rebuilding process is displayed by progress bar (4) and in the text field (5).
  23. When you finish reindexing, shut the window of utilityWhen the process is complete, close the utility window by clicking the Image Added button.

Reindexing of archive files is completedcomplete.

To reindex archive files without using the dialog boxwindow, in the command line, start the index_fs.exe utility with parameters. For instance, the "index.exe C, D" command will reindex archive files on disks C and D. To reindex archive files on all disks, use the "all" parameter

Examples:

  • index_fs --drives=C:\,E:\,\\172.19.2.77\VIDEO—reindex video archive files on the specified disks.
    Info
    titleNote

    \\IP address of the network disk\the folder name of the video archive—used to specify the network disk.

  • index_fs --drives=all—reindex all disks used for the archive storage.
  • index_fs --help—displays the short guide of the applied parameters.
Note
titleAttention!

In order for Axxon PSIM to start working with new indexes, it is necessary to you must restart the video.run module or restart the entire Axxon PSIM after reindexing.

...