Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Run the command line using the cmd command to the folder with the C:Program Files (x86)\Axxon PSIM\Tools utility folder.
  2. Specify the path to the folder with archive recordings or to a specific file.
    To simplify the export in the ArchProbe utility, you can check the integrity of video frames by displaying the frame hash and title text.
    Example of commands: 
    1. To check the integrity of video frames:
      Code Block
      C:\Program Files (x86)\Axxon PSIM\Tools>ArchProbe -p "E:\VIDEO\20-06-25 08"

      Image Added

    2. To check titles:
      Code Block
      C:\Program Files (x86)\Axxon PSIM\Tools>ArchProbe -p "E:\VIDEO\20-06-25 08" --titles

      Image Added

As a result, the system displays the information about each frame of the specified video archive.