Go to documentation repository
Page History
The figure shows the Access Manager interface object settings panel.
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
1
ID field
Automatically
Displays the identification number of the Access Manager interface object in the system
Whole nonnegative number
-
Depends on number of accessible Access Manager objects in the system
2
Name field
Setting the value in the field
Sets the number of the Access Manager object in the system
Latin, Cyrillic and special symbols
Access Manager
Case-insensitive character string (letters, digits, special symbols excepting > and <).
From 1 to 60 symbols
3
Disable checkbox
Settings checkbox
Sets the Access Manager object state in the system (enabled or disabled)
Boolean type
No
Yes – the Access Manager object is not used in the system.
No – the Access Manager object is used and active
4
Display drop-down list
Selecting the value in the list
Sets the Display parent object for the Access Manager object
Name of created Display objects
Parent Display name
Depends on the number of the Display objects
Position group
The Position group | ||||||
1 | ||||||
Fix position checkbox | Settings checkbox | Is used if it's required to specify coordinates of the Access Manager window and forbid its moving | Boolean type | No | Yes – position of the Access Manager window is fixed. No – position of the Access Manager window can be changed. |
2 | Monitor drop-down list | Selecting the value in the list | Sets the number of monitor on which the Access Manager window will be displayed | List of accessible computer monitors | Monitor 1 | Depends on the number of connected computer monitors |
3 | X: | Setting the value in the field | Sets X coordinate of the upper left corner of the Access Manager window | % of screen width | 0 | From 0 to |
M*100, where |
M is a number of computer monitors | |||||
Y: | Setting the value in the field | Sets Y coordinate of the upper left corner of the Access Manager window | % of screen height | 0 | From 0 to |
M*100, where |
M is a number of computer monitors | |||||
W: | Setting the value in the field | Sets the Access Manager window width | % of screen width | 0 | From 0 to |
M*100, where |
M is a number of computer monitors | |||||
H: | Setting the value in the field | Sets the Access Manager window height | % of screen height | 0 | From 0 to |
M*100, where |
M is a number of computer monitors |
Access levels, Users, Time zones, Departments groups
8
Create checkbox
Checkbox
Sets possibility to create the corresponding object in the Access Manager window
Boolean type
Yes
Yes – creating the corresponding object from the Access Manager window is allowed.
No – creating the corresponding object from the Access Manager window is forbidden.
Delete checkbox
Checkbox
Sets possibility to delete the corresponding object in the Access Manager window
Boolean type
Yes
Yes – deleting the corresponding object from the Access Manager window is allowed.
No – deleting the corresponding object from the Access Manager window is forbidden.
Edit checkbox
Checkbox
Sets possibility to edit the corresponding object in the Access Manager window
Boolean type
Yes – editing the corresponding object from the Access Manager window is allowed.
No – editing the corresponding object from the Access Manager window is forbidden.
| Out of groups |
| 4 | Create users with APB checkbox | Checkbox | Sets the default setting for the user antipassback parameter | Boolean type | No | Yes - by default, the users are created with enabled antipassback No - by default, the users are created with disabled antipassback |
5 | New departments are visible in root checkbox | Checkbox | Sets availability of new created departments in the Access Manager hierarchy root | Boolean type | Yes | Yes – new departments are available in the Access Manager hierarchy root No – new departments are not available in the Access Manager hierarchy root |
| 6 | Tab navigation buttons | Click the button | Buttons switch the active tab | - | - | - |
Departments tab
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
1 | Departments tree | Settings checkbox | Sets available departments in the Access Manager window | Boolean type | Set of boolean variables | Department will be available in the Access Manager window if checkbox is set close to it |
Access levels tab
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
1 | Mode drop-down list | Selecting the value in the list | Sets the access restriction mode for access levels in the Access Manager interface object | - | Prohibition | Prohibition - restrict the access Permission - allow the access |
| 2 | Access levels tree | Checkbox | Specifies the access levels, the access to which should be configured | Boolean type | A set of boolean variables | If the checkbox is set for the access level, the selected access restriction mode will be applied to it in the Access Manager interface object |
| 3 | Actions button | Selecting the value in the list | Opens a list of actions for managing the access levels tree | - | - | Minimize - minimizes all access levels in the tree Expand - expands all access levels in the tree Select all - sets the checkboxes for all access levels Remove all - removes checkboxes for all access levels Search - opens the Access level or folder search window for access level or folder searching by the name or identifier |
Time zones tab
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
1 | Mode drop-down list | Selecting the value in the list | Sets the access restriction mode for time zones in the Access Manager interface object | - | Prohibition | Prohibition - restrict the access Permission - allow the access |
| 2 | Time zones tree | Checkbox | Specifies the time zones, the access to which should be configured | Boolean type | A set of boolean variables | If the checkbox is set for |
| the time zone, the selected access restriction mode will be applied to it in the Access Manager interface object | ||||||
| 3 | Actions button | Selecting the value in the list | Opens a list of actions for managing the time zones tree | - | - | Minimize - minimizes all time zones in the tree Expand - expands all time zones in the tree Select all - sets the checkboxes for all time zones Remove all - removes checkboxes for all time zones Search - opens the Time zone or folder search window for time zone or folder searching by the name or identifier |
Right tab
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
Object management rights group | ||||||
1 | Create checkbox | Checkbox | Sets possibility to create the corresponding object in the Access Manager window | Boolean type | Yes | Yes – creating the corresponding object from the Access Manager window is allowed. No – creating the corresponding object from the Access Manager window is forbidden. |
Delete checkbox | Checkbox | Sets possibility to delete the corresponding object in the Access Manager window | Boolean type | Yes | Yes – deleting the corresponding object from the Access Manager window is allowed. No – deleting the corresponding object from the Access Manager window is forbidden. | |
Edit checkbox | Checkbox | Sets possibility to edit the corresponding object in the Access Manager window | Boolean type | Yes | Yes – editing the corresponding object from the Access Manager window is allowed. No – editing the corresponding object from the Access Manager window is forbidden. | |
| 2 | Check all button | |||||
| 3 | Uncheck all button | |||||
| Forbid to delete group | ||||||
| 4 | Non-empty departments checkbox | Settings checkbox | Forbids to delete departments if there are users in them | Boolean type | No | Yes – non-empty departments cannot be deleted. No – non-empty departments can be deleted. |
| 5 | Assigned Access Levels checkbox | Settings checkbox | Forbids to delete access levels if they are assigned to user(s) | Boolean type | No | Yes – assigned access levels cannot be deleted. No – assigned access levels can be deleted. |
| 6 | Assigned Time Zones checkbox | Settings checkbox | Forbids to delete time zones if they are assigned to access levels | Boolean type | No | Yes – assigned time zones cannot be deleted. No – assigned time zones can be deleted. |
| Out of groups | ||||||
| 7 | Allow user type change checkbox | Settings checkbox | Enables the ability to change the user type | Boolean type | No | Yes – the user type change is allowed. No – the user type change is not allowed. |
Access cards tab
Readers tab
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
1 | Minimum drop-down list | Selecting the value in the list | Sets the minimum number of access cards that should be assigned to the user | List of values | Unlimited |
|
| 2 | Maximum drop-down list | Selecting the value in the list | Sets the maximum number of access cards that should be assigned to the user | List of values | Unlimited |
|
| 3 | Common format drop-down list | Selecting the value in the list | Sets the access cards format | List of values | Default |
|
Readers tab
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
1 | Confirm card entered by operator checkbox | Settings checkbox | Sets requirement to confirm card code entering by operator | Boolean type | No | Yes – operator confirmation is required to assign access card to user. No –operator confirmation is not required to assign access card to user. |
2 | List of readers | Settings checkbox | Sets list of control readers used for entering user access cards | List of created reader objects in the system | Set of boolean variables | The reader will be available to enter user access card if checkbox is set close to it |
Cameras tab
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
1 | Cameras column | Automatically | Displays list of Camera objects created on the Hardware tab of the System settings dialog window | List of created Camera objects in the system | Names of Camera objects | Depends on number of accessible Camera objects in the system |
2 | Use checkbox | Settings checkbox | Sets possibility to use camera for assigning photo to user in the Access Manager window | Boolean type | No | Yes – camera can be used for assigning photo. No – camera can't be used for assigning photo |
| 3 | Compression drop-down list | Selecting the value in the list | Sets the compression level of the selected video stream | - | Do not compress | Do not compress - compression of the camera video stream is disabled Level 1 - the lowest level of video stream compression .... Level 5 - the highest level of video stream compression |
4 | Gateway drop-down list | Selecting the value in the list | Sets the Gateway object used for receiving video signal from camera | List of created Gateway objects in the system | Names of Gateway objects | Depends on number of accessible Gateway objects in the system |
Others tab
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
1 | Full name drop-down list | Selecting the value in the list | Sets the way of defining of users record duplicates by name, surname, patronymic | List of available combinations | Not used | Not used – adding users with the same full name is allowed. Surname, name – adding users with the same name and surname and different patronymic is forbidden. Surname, name, patronymic – creating users with the same full name is forbidden. |
| 2 | External ID checkbox | Settings checkbox | Indicates whether the users records should be checked for external ID duplicates | Boolean type | No | Yes – creating users with the same external ID is forbidden. No – creating users with the same external ID is allowed. |
| 3 | PIN code checkbox | Settings checkbox | ||||
| 4 | Vehicle license plate checkbox | Settings checkbox | Indicates whether the users records should be checked for vehicle license plate number duplicates | Boolean type | No | Yes – creating users with the same license plate number is forbidden. No – creating users with the same license plate number is allowed. |
Yes – assigned time zones cannot be deleted.
No – assigned time zones can be deleted.Yes – assigned access levels cannot be deleted.
No – assigned access levels can be deleted.
| 5 |
Yes – non-empty departments cannot be deleted.
No – non-empty departments can be deleted.
| Recognition Server drop-down list | Selecting the value in the list | Displays a list of Face Recognition Server objects created on the Hardware tab of the System Settings dialog box | List of Face Recognition Server objects created in the system | - | Depends on number of accessible Face Recognition Server objects in the system |
| 6 | RestAPI port field | Setting the value in the field | Specifies the communication port to connect to the Face Recognition Server through the REST API. By default, it is necessary to set the 10000 value. | Number | 0 | - |
Yes – the user type change is allowed.
No – the user type change is not allowed.
Standard fields tab
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
1 | Name of field column | Automatic | Displays a list of standard user fields | - | Names of standard user fields | - |
| 2 | Drop-down list | Selecting the value in the list | Specifies the permissions to edit, specify, or hide the standard fields from the Access Manager interface object | - | Depends on the standard field | Edit - the field is displayed in the list of user parameters while viewing and editing and is available for editing Hidden - the field is not displayed in the list of user parameters while viewing and editing Read only - the field is displayed in the list of user parameters while viewing and editing but is not available for editing Mandatory - this field is displayed and is required when creating a new user |
| 3 | Category column | Setting the value in the field | Specifies the name of the category to which the standard field belongs | - | Depends on the standard field | Any value |
Additional fields tab
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
1 | Name of field column | Automatic | Displays a list of additional user fields | - | Names of additional user fields | - |
| 2 | Drop-down list | Selecting the value in the list | Specifies the permissions to edit, specify, or hide the additional fields from the Access Manager interface object | - | Depends on the additional field | Edit - the field is displayed in the list of user parameters while viewing and editing and is available for editing Hidden - the field is not displayed in the list of user parameters while viewing and editing Read only - the field is displayed in the list of user parameters while viewing and editing but is not available for editing Mandatory - this field is displayed and is required when creating a new user |
| 3 | Category column | Setting the value in the field | Specifies the name of the category to which the additional field belongs | - | Depends on the additional field | Any value |