Go to documentation repository
The settings panel of the SIP-operator system object is shown in the pictures figures below.
Table The table describes the setting parameters of the SIP-operator system object.
№ | Parameter | Method for setting the parameter value |
Parameter description |
Representation | Default value |
Value range | |
| 1 | The |
Identification number* | Automatically |
Displays the identification number |
Sequence of numbers
-
>=0
Enables binding of a SIP-operator to Axxon PSIM user rights. Activates the User drop-down list.
Note. It is used when the User rights are selected by default on the operator's SIP panel.
Yes - binding of a SIP-operator to Axxon PSIM user rights is enabled
No - binding of a SIP-operator to Axxon PSIM user rights is disabled
of the SIP-operator object in the video surveillance system with distributed architecture | Digits, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the SIP-operator object in the video surveillance system with distributed architecture | |||
| 2 | The Name* | Enter the value in the field | Sets the name of the SIP-operator object in the video surveillance system with distributed architecture | Latin alphabet, Cyrillic, digits, and service characters | SIP-operator | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
| 3 | The Disable | Set the checkbox | Disables the SIP-operator object in the video surveillance system with distributed architecture | Boolean type | Clear | Set—the SIP-operator object is disabled and isn't used Clear—the SIP-operator object is enabled and used |
| 4 | The SIP-terminal drop-down list | Select the value from the list | Sets the SIP-terminal parent object of the system with distributed architecture to which the given SIP-operator object belongs | Names of the SIP-terminal objects registered in the system | Name of the SIP-terminal parent object |
| Depends on the number of the |
| SIP-terminal objects in the |
| video surveillance system with distributed architecture | |
| 5 | The Device priority |
drop-down list |
| Select the value from the list | Sets the priority of a call from this operator in the incoming calls window of the SIP panel |
| Sequence of numbers |
| Clear |
From 1 to 10.
|
|
|
| ||||||
The User group | ||||||
6 | The Number | Enter the value in the field | Sets the identification number of the operator to which you can call | Digits, letters, periods, hyphen, dash, and underscore | NA | A line containing a sequence of any characters (numbers, letters, periods, hyphens, dash, and underscore) |
| 7 | The Bind operator to user rights checkbox | Set the checkbox | Enables binding of an SIP operator to Axxon PSIM user rights. Activates the User drop-down list. Note. It is used when you select the default operator on the SIP panel to which the user rights are assigned | Boolean type | Clear | Set—binding of an SIP operator to Axxon PSIM user rights is enabled Clear—binding of an SIP operator to Axxon PSIM user rights is disabled |
| 8 | The User drop-down list | Select the value from the list | Sets the user under which you must register in Axxon PSIM | Names of the User objects registered in the system | NA | Depends on the number of the User objects in the system |
*Name of the element isn't displayed in the settings panel of the given object
The Server connection tab (only for the SIP-client terminal type)
Table The table describes the setting parameters of the Server connection tab.
№ | Parameter | Method for setting the parameter value |
Parameter description |
Representation | Default value |
Value range |
| 1 |
| The Login field | Enter the value in the field | Sets the username for connecting to the SIP server. Only for the SIP- |
client terminal type | Latin alphabet, Cyrillic |
| , digits, and service characters |
| NA | A line |
| containing a sequence of any |
| characters (letters, |
| digits, service |
| characters) |
| 2 |
| The Password field | Enter the value in the field | Sets the password for connecting to the SIP |
server. Only for the SIP-client terminal type | Latin alphabet, Cyrillic |
| , digits, and service characters |
| NA | A line |
| containing a sequence of any |
| characters (letters, |
| digits, service |
| characters |
The Address book tab
Table The table describes the setting parameters of the Address book tab.
№ | Parameter | Method for setting the parameter value |
Parameter description |
Representation | Default value |
Range of values
Value range | ||||||
| The Address books | ||||||
-
| table | ||||||
| 1 | The Number drop-down list | Select the value from the list | Selects the identifier of the Address book object | Identifiers of the | ||
| Address book objects registered in the system |
| NA | Depends on the number |
| of the Address book objects in the system |
| The Name |
drop-down list | Select the value from |
| the list |
| Selects the name of the |
| Address book object in Axxon PSIM, the numbers of which are available for this SIP operator | Names of the Address book objects registered in the system |
| NA | Depends on the number |
| of the Address book objects in the system | |||
| 2 | The All button | Click the button | Adds all existing |
| Address book objects to the table |
| NA |
| NA |
| NA | |||
| 3 | The Range button | Click the button | Opens the Add address books window to add |
| several address books |
| NA |
| NA |
| NA |