Go to documentation repository
...
The INC_MANAGER object sends events given in the table. Procedure is Procedures are started when the corresponding event appears. Format of event procedure for the Incident manager object:
| Code Block |
|---|
OnEvent("INC_MANAGER","_id_","_event_") |
occurs.
| Events | Events description | Paremeters | Parameters description | Event | Description
|---|---|---|---|---|
| Comment | ||||
CLOSE_CLICK | Click the Close button in the interface | The event is generated when an incident is closed without being processed by the operator in the Incident manager interface | ||
| CLOSE_ALL_CLICK | Click the Close all button in the interface | The event is generated when all incidents are closed without being processed by the operator in the Incident manager interface | ||
SELECT | Click | |||
| an incident in the interface | The event is generated if the operator left-clicks or right-clicks the incident in the Incident manager interface | |||
| ACTIVATE_EVENT | The operator selects the event (click the event with the mouse) | alarm_time<> | Time when the event occurs | |
| event_guid<> | Event ID (generated randomly for each event) | |||
| objtype<> | Object type (for example, CAM, GRELE, and so on | |||
| ) | ||||
action<> | Action type (for example, MD_START, DISARM, and so on) | |||
| SETUP_FILTER | Search and display of certain events and objects that match all selected filter criteria at a time | Works the same way as the filter in the settings of the Incident manager interface (see Event information) when you click the Filter button |