Requirements for the operation of the Water Level Detection are level detector are given in the table:
| Camera | - You must use only color cameras
- Resolution must be at least
|
640x360 - 640x360
- Camera shake must not result in image offsets greater than 1% of the frame size
| Note |
|---|
| Correct operation of the detector isn't guaranteed if you use frames that were masked before they got into Axxon One by an IP camera or similar methods. |
|
| Lighting | - The measuring scale and its divisions for determining the water level must be clearly visible in the scene. In conditions of insufficient or excessive lighting (night or light-striking), we don't guarantee the stable operation of the analytics
|