Go to documentation repository
The Architecture tab allows you to create a distributed video surveillance and audio control system and is used to configure connection parameters and data exchange between the system components.
The Connection connection settings table can be accessed from the the Architecture tab. This table is used to configure the connection between computers in the distributed system and distribute the information about the events registered in the system. The connection settings table is shown in the figure.
...
Table describes the elements of the connection settings table.
№ | Column | Description | Value |
1 | Computer | Network name of the computer |
Determined by |
OS | |||
2 | Name | Computer name in the system | Set in the Hardware |
tab | |||
3 | Connection | Checkbox | If the checkbox is set |
—the computer is connected If the checkbox is clear—connection wasn't established | ||
4 | With computer | List of names of the network computers |
Determined by |
OS | |
5 | IP |
address | IP |
address of the computer in the local |
network (if connected via the |
internet, then public IP |
address) |
Determined by |
OS or assigned manually. When the IP |
address of the |
server/remote administrator's workstation is edited, the IP |
address for the current |
server/remote administrator's workstation only is changed. For other |
servers/remote administrator workstations, the IP |
addresses |
must be changed individually. If the entered address is already assigned to a computer in the system, the address |
is assigned to |
the computer being configured, and the corresponding warning message |
is displayed. The address of the computer that previously had this address |
is reset | |||
6 | Send events | Checkbox | If the checkbox is set |
—there is a permission to send events to the computer it is connected to If the checkbox is |
clear—there is no permission to send events | ||
7 | Type | List of the system objects, from which the events |
are transmitted to the selected computers |
Determined by the list of the registered objects | |||
8 | Event | Checkbox in the list next to each item in the event list, corresponding to the device selected in the Type column | If the checkbox is set |
—this event |
is transmitted If the checkbox is |
clear—this event |
isn't |
transmitted |
| Info | ||
|---|---|---|
| ||
To enter the IP address of the computer of a distributed system, enter the "?" character in the IP address column while holding down the Shift key. After this, you must restart Axxon PSIM. |