The Keyboard object is used to register and configure a special keyboard in Axxon PSIM. The keyboard is used for the operational control of the major main functions of the digital video surveillance system with the distributed architecture based on Axxon PSIM.

The settings panel of the Keyboard object is shown in the figure.

Image Modified

Table The table describes the parameters of the settings corresponding to the elements of the settings panel of the Keyboard object.

 

Parameter

Method for setting the parameter value

Parameter description

Symbols used

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Keyboard object in the

digital

video surveillance system with

the

distributed architecture

Sequence of numbers

-

Digits, letters, periods, hyphen, dash, and underscore

NA

From 1 and above.

Depends on the number of the Keyboard objects in the

digital

video surveillance system with

the

distributed architecture

2

The Name*
field

Enter the value

into

in the field

Sets the name of the Keyboard object in the

digital

video surveillance system with

the

distributed architecture

Latin alphabet, Cyrillic, digits and service characters

Keyboard

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive

Number of

symbols –

charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Sets the state of the Keyboard object (enabled or disabled)

Disables the Keyboard object in the

digital

video surveillance system with

the

distributed architecture

Boolean type

Clear

Set

the Keyboard object is disabled and isn't used

Clear

the Keyboard object is enabled and used

4

The Computer
drop-down list

Select the value from the list

Sets the Computer parent object of the

digital

system with

the

distributed architecture

,

to which the

given

given Keyboard object belongs

Name

Names of the Computer objects registered in the system

Name of the Computer parent object

Depends on the number of the Computer objects in the

digital

video surveillance system with

the

distributed architecture

The Settings group

5

The X field

Enter the value

into

in the field

Sets the coordinate on the horizontal X axis of the upper left corner of the object selection window

,

to which the given command refers

% of the screen width

Not defined
NA

From 0 to

100

100%


6

The Y field

Enter the value into the field

Sets the coordinate on the vertical Y axis of the upper left corner of the object selection window

,

to which the given command refers

% of the screen height

Not defined

NA

From 0 to

100

100%


7

Control devices*

Set the switch in the required

radio button

position

Sets the interface objects

, which will

that can be controlled using the

Keyboard

keyboard

Types

List of device types for control

devices

Operate all

Operate all

– the Operator

—the operator can control all interface objects according to the settings in the

configuration file of the Keyboard

keyboard configuration file 

From list

– the Operator

—the operator can control only those interface objects

, which

that are

sepcified

specified in the list below

8

The Type
drop-down list

Select the value from the list

Sets the type of the interface object

, which

that can

also

be controlled using the

Keyboard

 keyboard

Name


Names of the object types registered in the system

Not defined
NA

Depends on the number of the interface object types created in the

digital

video surveillance system with

the

distributed architecture

9

The Number
drop-down list

Select the value from the list

Sets the identification number of the interface object

, which

that can

also

be controlled using the

Keyboard

keyboard

Sequence of numbers

Not defined

NA

Depends on the number of the created devices of the type selected in item 8 in the

digital

video surveillance system with

the

distributed architecture

10

The Name
drop-down list

Automatically

Indicates the name of the device selected in the item 9

Name of the objects of the selected type registered in the system

Not defined

NA

Depends on the number of the created devices

,

of the type selected in item 8 in the

digital

video surveillance system with

the

distributed architecture

*Name of the element isn't displayed in the settings panel of the given object.