The You can create the Sensor system object is created under on the basis of the Video Capture Devicecapture device object.

The You can create and configure the Sensor object is created and main parameters are set in the following order:

  1. Go to the Hardware tab in (1) on the settings panel of of Axxon PSIM™ (1).
  2. Create On the basis of the Video capture device object, create the Sensor system object under the Video Capture Device object or select the select the corresponding object in the object tree in the the Hardware tab on the settings panel of Axxon PSIM (2).
  3. Specify the ID and name of the Sensor object and select the Video Capture Device object to become the parent of capture device object on the basis of which you want to create the Sensor object (3).

    Info
    titleNote

    If the Sensorsensor-Relay relay card is used, then specify that video capture card with ADC to which the Sensorthe sensor-Relay relay card is connected.

  4. Select the channel number matching the number of output connector to which the sensor is connected (4).

  5. In the group of switches, select the alarm mode of the sensor: at switch on or at switch off. By default, the alarm at switch on mode is selected (5).
    The executive actuating device corresponding to the Sensor system object operates in one of the two modes: alarm at switch on or alarm at switch off.
     

    Info
    titleNote

    Sensors connected to Panasonic IP - devices (of the i-Pro series ) trigger generate alarms only at switch off.

    When the you select the alarm at switch off mode is selected, the normal state of the sensor is open. When the sensor closes, it triggers, and as a result, the corresponding actions specified in Axxon PSIM are performed in Axxon PSIM™.

  6. In the Hardware dropdown list Detector drop-down list (6), select the type of executive actuating device used as the detector in the guarded area (6)on the protected facility.
    The Hardware Detector parameter is used for selecting the icon on the interactive map. This parameter is essential for better perception of information ( displayed on the map as object icons ) by Operator the operator and for real-time intercepting by Operator if requiredprompt operator intervention if necessary.

  7. Types of detectors available for

  8. the
  9. the Sensor system object are given in the table.

  10. Hardware
  11. Detector

    Description

    Infrared

    Icon

  12. of
  13. on the interactive map for

  14. themotion
  15. the motion detectors

  16. PIR
  17. Ceiling

    Icon

  18. of
  19. on the interactive map for

  20. the 
  21. the device installed on the ceiling

  22. of
  23. on the

  24. guarded area
  25. protected facility

    Glass

    Icon

  26. of
  27. on the interactive map for

  28. the 
  29. the device installed on the window of the

  30. guarded area 
  31. protected facility and responding when the window is broken

  32. Fire
  33. Heat

    Icon

  34. of
  35. on the interactive map for

  36. the device
  37. the device responding to changes of

  38. heat 
  39. heat conditions

  40. in
  41. on the

  42. guarded area
  43. protected facility

    Window

    Icon

  44. of
  45. on the interactive map for

  46. the 
  47. the device installed some distance away from the

  48. windowand
  49. window and responding when the window is broken

    Smoke

    Icon

  50. of
  51. on the interactive map for

  52. the 
  53. the device responding to smoke

  54. in the guarded area  
  55. on the protected facility

    Reed switch

    Icon

  56. of
  57. on the interactive map for

  58. the 
  59. the device responding to locking/

  60. unlocking 
  61. unlocking a window, door,

  62. etc.
  63. and others

  64. Click the Apply button to save the changes.

...

After you create the sensor, it is in the "Armed" state. To change the

...

sensor state, use a macro (see

...

Creating and using macros

...

) or control the

...

sensor on the

...

map (see

...

Configuring the interactive map for object state indication and controlling the objects and Operations with sensors

...

). If the

...

sensor is armed, then at the

...

sensor switching on/off the "Alarm" event

...

is generated depending on the alarm mode

...

setting—see step 5 above. If the

...

sensor is disarmed, the "Closed"/"Opened" events

...

are generated, respectively.

Info
titleNote.

Axxon PSIM requests sensor state 3 three times per second. Short-term triggering triggerings that last for less than 1/3 of a second can be skipped.

Creating Creation and configuring configuration of the Sensor system object is completedcomplete.