Go to documentation repository
The You can create the Sensor system object is created under on the basis of the Video Capture Devicecapture device object.
The You can create and configure the Sensor object is created and main parameters are set in the following order:
Specify the ID and name of the Sensor object and select the Video Capture Device object to become the parent of capture device object on the basis of which you want to create the Sensor object (3).
| Info | ||
|---|---|---|
| ||
If the Sensorsensor-Relay relay card is used, then specify that video capture card with ADC to which the Sensorthe sensor-Relay relay card is connected. |
Select the channel number matching the number of output connector to which the sensor is connected (4).
In the group of switches, select the alarm mode of the sensor: at switch on or at switch off. By default, the alarm at switch on mode is selected (5).
The executive actuating device corresponding to the Sensor system object operates in one of the two modes: alarm at switch on or alarm at switch off.
| Info | ||
|---|---|---|
| ||
Sensors connected to Panasonic IP - devices (of the i-Pro series ) trigger generate alarms only at switch off. |
When the you select the alarm at switch off mode is selected, the normal state of the sensor is open. When the sensor closes, it triggers, and as a result, the corresponding actions specified in Axxon PSIM are performed in Axxon PSIM™.
In the Hardware dropdown list Detector drop-down list (6), select the type of executive actuating device used as the detector in the guarded area (6)on the protected facility.
The Hardware Detector parameter is used for selecting the icon on the interactive map. This parameter is essential for better perception of information ( displayed on the map as object icons ) by Operator the operator and for real-time intercepting by Operator if requiredprompt operator intervention if necessary.
Types of detectors available for
the Sensor system object are given in the table.
Detector | Description |
Infrared | Icon |
on the interactive map for |
the motion detectors |
Ceiling | Icon |
on the interactive map for |
the device installed on the ceiling |
on the |
protected facility | |
Glass | Icon |
on the interactive map for |
the device installed on the window of the |
protected facility and responding when the window is broken |
Heat | Icon |
on the interactive map for |
the device responding to changes of |
heat conditions |
on the |
protected facility | |
Window | Icon |
on the interactive map for |
the device installed some distance away from the |
window and responding when the window is broken | |
Smoke | Icon |
on the interactive map for |
the device responding to smoke |
on the protected facility | |
Reed switch | Icon |
on the interactive map for |
the device responding to locking/ |
unlocking a window, door, |
and others |
Click the Apply button to save the changes.
...
After you create the sensor, it is in the "Armed" state. To change the
...
sensor state, use a macro (see
...
...
) or control the
...
sensor on the
...
map (see
...
Configuring the interactive map for object state indication and controlling the objects and Operations with sensors
...
). If the
...
sensor is armed, then at the
...
sensor switching on/off the "Alarm" event
...
is generated depending on the alarm mode
...
setting—see step 5 above. If the
...
sensor is disarmed, the "Closed"/"Opened" events
...
are generated, respectively.
| Info | ||
|---|---|---|
| ||
Axxon PSIM requests sensor state 3 three times per second. Short-term triggering triggerings that last for less than 1/3 of a second can be skipped. |
Creating Creation and configuring configuration of the Sensor system object is completedcomplete.