The APB Areas allow controlling the number of users in the area and denying access when maximal visitors number is reached. The APB Areas can also be used for antipassback (see Configuring antipassback).

Note
titleImportantAttention!
At least two APB Areas corresponding to entrance and exit areas of the AIM controller are to must be configured in the system (see also Configure Configuring the AIM readers). If just one APB area is configured, the system will lock it when it is filled and it will be impossible to reset the counter. See also Example of APB Areas areas configuration.


The APB Area is configured on the Apollo APB Area object settings panel , that is created on the basis of the Apollo AAN object on the Hardware tab of the System settings dialog box.

Image Removed

APB area is configured as follows:

  1. Go to the settings panel of the Apollo APB Area object settings panel.
    Image RemovedImage Added
  2. In From the Number drop-down list, select the APB area number in the controller (1).
  3. In From the Connection with Axxon PSIM region drop-down list, select the Region object corresponding to this APB Area area (2). This Region object is to must be set as entrance or exit region of an Apollo the AIM reader (see also Configure Configuring the AIM readers).
  4. In From the Initial mode drop-down list, select the initial state of the APB area that will be set when writing configuration to controllerhardware: Closed or Opened (3).
  5. By default, the Use initial mode checkbox is set to use the initial mode. To disable the setting, clear the checkbox (4).
  6. In From the Mode when zone is closed drop-down list, select access rule for closed APB area, i.e. , that is, when maximum number of users in it is exceeded (4)5):
    1. Forbid access.
    2. Allow access.
    3. Allow access on specific reader.
  7. In From the Reader to get into zone when it has "closed" status drop-down list, select corresponding AIM reader (56).
  8. Specify In the Maximum number of persons in zone field, specify maximum number of people persons in the area a zone (67).
  9. If two cards are required to enter the zone, set the corresponding Require two cards checkbox (78).
  10. If users are to be allowed to enter the closed restricted zone if commands are enabledallowed, set the corresponding Let into restricted zone, if commands are allowed checkbox (89).
  11. If zone status is to must be changed at access if commands are enabledallowed, set the corresponding Change status while accessing, if commads are allowed checkbox (910).
  12. Click the Apply (10)button.
  13. To save the changes to the controller, write configuration to hardware.
Note
titleImportantAttention!
User counter in zone is reset when configuration is written.

...