Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Displayed on the video surveillance monitor over the camera name (disabled by default to reduce GPU load, see Setting the parameters of the Monitor interface window).
  2. Added to the name of the export file from the monitor interface monitor (AVI, BMP/JPEG) and for when printing a frame printing.
  3. Displayed in the Event Viewer window in the Additional info column.

...

  1. Go to the Hardware tab in the System settings window.
  2. In the object tree on the Hardware tab, select the Camera object corresponding to the adjusted camera that you want to adjust.
  3. Go to the Advanced settings tab on the settings panel of the Camera object.
  4. In the Additional info field, specify the a line of at least 100 characters.

    Info
    titleNote

    The color of additional information displayed on the surveillance monitor changes according to the state of the Cameracamera. For example, if the Camera camera is recording, the text is red; otherwise, it is white. You can set an unchanging arbitrary color using the MonitorExtraTextColor parameter of the MonitorExtraTextColor key of the HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\AxxonSoft\PSIM\Video registry key section (for details, see see Registry keys reference guide).

  5. To save the changes in Axxon PSIM, click the Apply button.

...